Toshiba MMW-AP0481CHQ-E Manual
Also see for MMW-AP0481CHQ-E: Installation manualService manual
3MMW-AP___1CHQE18-361Allowable length / height difference of refrigerant piping■SystemHigh temperature Hot Water Module (H-HWM) is connectable to only SHRM-e.The system does not work when it connect to the SMMS-i, SMMS-e, MiNi-SMMS-e and SHRM-i.The Fresh Air intake type and Air to Air Heat Exchanger with DX Coil cannot be connected with the samerefrigerant system.SHRM-e system restrictionsIn case of connecting at least one Hot Water Module in SHRM-e system, all of Flow Selector unit type should beSingle port type Flow Selector unit (long piping model) or Multi port type Flow Selector unit. Model name of usableFlow Selector unit: RBM-Y1124FE, RBM-Y1804FE, RBM-Y2804FE, RBM-Y1801F6PE, RBM-Y1801F4PE TheFresh Air intake type and Air to Air Heat Exchanger with DX Coil cannot be connected with the same refrigerantsystem. The SHRM-e system can also be connected to a Mid temperature Hot Water module (M-HWM).M-HWM: Mid temperature Hot Water ModuleH-HWM: High temperature Hot Water ModuleRestriction on Mid temperature Hot Water Module (M-HWM) and High temperature Hot Water Module(H-HWM) connection*1: Ratio of connected total indoor unit capacity to outdoor unit capacity.*2: Maximum indoor connection capacity is varied depending on the height difference between indoor unit H2, H4, H5.*3: M-HWM and H-HWM connecting capacity should be smaller than standard indoor unit.NOTEDesign the system that total capacity of simultaneous heating operation is 100% or less. If total capacity ofsimultaneous heating is over 100%, then each indoor units or Hot Water Module performance is descended.M-HWM connection With M-HWM & H-HWMMax. No. of combined outdoor units 3 unitsMax. capacity of combined outdoor units 54 HPMax. No. of combined indoor units 32 unitsMax. capacity of combinedindoor units and M-HWM & H-HWMH2 ≤ 15 m 200%H2 > 15 m 125%Indoor connection capacity(*1)Total Standard indoor unit + M-HWM + H-HWM 90 - 200% (*2) (*3)Standard indoor unit + M-HWM 90 - 135% (*2) (*3)AllowedcapacityStandard indoor unit 50 - 120% (*2)M-HWM 0 - 67.5% (*2) (*3)H-HWM 0 - 100% (*2) (*3)M-HWM + H-HWM 0 - 100% (*2) (*3)Standard indoor unit + M-HWM 90 - 135% (*2) (*3)Number of combined indoorunits, M-HWM and H-HWMTotal Standard indoor unit + M-HWM + H-HWM 2 - 32Standard indoor unit + M-HWM 2 - 32AllowednumberStandard indoor unit 2 - 32M-HWM 0 - 14H-HWM 0 - 12M-HWM + H-HWM 0 - 14Standard indoor unit + M-HWM 2 - 32Combination of indoor units SHRM-eStandard indoor unit + M-HWM + H-HWM H2, H4, H5 ≤ 15 m Max.200% (Standard indoor unit <120%)H2, H4, H5 > 15 m Max.125% (Standard indoor unit <100%)Standard indoor unit + M-HWM H2, H4, H5 ≤ 15 m Max.135% (Standard indoor unit <120%)H2, H4, H5 > 15 m Max.125% (Standard indoor unit <100%) |
Related manuals for Toshiba MMW-AP0481CHQ-E
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved