©note) Information in this document is subject to change without notice.Rev. 20211217TOSHIBA Industrial Magnetron E3327TYPICAL OPERATION (2) (5)Anode power supply Three phase full wave rectifiedTwo typical operations are different with average output powers.Two typical operations are as follows.ex.1 ex.2 UnitFrequency 2460 2460 MHzFilament voltage (pre-heating) 5 5 V acFilament voltage (operating) 0.5 0 V acPeak anode voltage 7.2 7.2 kVAverage anode current 950 1150 mA dcAverage output power 5 6 kWElectromagnet current -1.7 -2 A dc Note 6Ambient temperature 25 25Load VSWR 2.5 2.5 - Note 9Load VSWR phase sink sink Note 9Pulling (VSWR2) 9 9 MHzCoolingAnode Water cooling Note 7Filter box Forced air cooling Note 8Output antenna Forced air cooling Note 8Notes (1) None of the absolute maximum ratings should beexceeded under any circumstances even for aninstant or a transient, since to do so may causedamage to the tube. A combination of themaximum rating conditions can not be guaranteed.(2) All the voltage parameters are in reference to thecathode voltage.(3) “Vn” is typical filament voltage for average anodecurrent. (see Fig. 4)Filament voltage has to be immediately reducedafter applying the anode voltage, in accordancewith Fig 4.(4) This condition is not drenched by water.(5) It makes used of thermoswitch, which gives opensignal in the case of the temperature greater than80±5 on the tube. Because of magnetron defendsoverheat.(6) Electromagnet data (parallel connection);Re = 4.1 ΩLe = 20 mHDefinition of electromagnet current direction;See Fig 8.(7) See Fig 2.(8) See Fig 3.(9) Waveguide configurationMagnetronE3327WaveguideRF couplerFig 9TaperedWaveguideVariable mismatch(double slug tuner)High powerCirculatoror isolatorLoad