5-57ROUTING SWITCHER SYSTEM (E)ODDField 1EVENField 2ODDField 3EVENField 4RS-422ASwitching Command Switching ExecutedSwitching Command Switching ExecutedODDField 1EVENField 2ODDField 3EVENField 4ODDField 1EVENField 2ODDField 3EVENField 4S-BUSSwitching ExecutedSwitching ExecutedODDField 1EVENField 2ODDField 3EVENField 4Switching CommandSwitching CommandODDField 1EVENField 2ODDField 3EVENField 4RS-422AODDField 1EVENField 2ODDField 3EVENField 4ODDField 1EVENField 2ODDField 3EVENField 4S-BUSODDField 1EVENField 2ODDField 3EVENField 4ODDField 5Switching Command Switching ExecutedSwitching Command Switching ExecutedSwitching Command Switching ExecutedSwitching Command Switching ExecutedODDField 1EVENField 2ODDField 3EVENField 4RS-422AODDField 1EVENField 2ODDField 3EVENField 4ODDField 1EVENField 2ODDField 3EVENField 4S-BUSODDField 1EVENField 2ODDField 3EVENField 4Switching Command Switching ExecutedSwitching Command Switching ExecutedSwitching Command Switching ExecutedSwitching Command Switching Executed5-8. Signal Switching Timing5-8. Signal Switching TimingFor DVS-V3232B/V6464B and HDS-V3232, a SWITCHING FIELD which switch signals from the control terminal canbe set. The SWITCHING FIELD are set using menu item “Z” of the secondary station and any SWITCHING FIELDmode (ODD, EVEN, FIELD, ASYNC) can be selected.The signal switching timing depends on whether it is controlled by RS-422A or the S-BUS.The following shows the timing charts of RS-422A and S-BUS for each SWITCHING FIELD mode...... When SWITCHING FIELD “EVEN” is set..... When SWITCHING FIELD “ODD” is set..... When SWITCHING FIELD “FIELD” is set..... When SWITCHING FIELD “ASYNC” is setThe signals will be switched immediately after the switching command is received regardless of the control method andprotocol used.