Weighing FunctionsSIWAREX FTA5-70AWI gravim. big bag emptying: continue with step 0AWI catchw. emptying: continue with step 05.5.6 Description of weighing step 5 - EmptyIf step 5 is blocked, then no activities in step 5 are performed. After enabling step5, the empty signal is output. If emptying has finished, a check is performed todetermine whether a check stop requirement exists and if not, the switch to step 6(only with totalising weighing - AWI) or to step 0.5.5.7 Description of weighing step 6 - End control AWIIf step 6 is blocked, then no activities in step 6 are performed. After step 6 is enabled,a check is performed to determine whether standstill 2 exists. If YES then the weightrecording and totalling are performed. A check is then performed to determine whethera check stop requirement exists and if not, the switch to step 0 is made.5.5.8 Description of Weighing Step 7Weighing step 7 is currently not utilised (Reserve).5.5.9 DR 4 - Monitoring time for LoggingIf weighing result logging is activated with an instruction or automatically,SIWAREX FTA monitors whether the procedure has been completed within thedefined amount of time. If not, an error is generated.5.5.10 DR 4 - Device for log outputLogs can be output to a connected printer or to the Micro Memory Card (MMC).The contents of the log are defined in data records DR 40 to DR 43.5.5.11 DR 4 - Basis weight for the limit value 1The limit values can be defined in reference to the gross weight or the net weight ofthe scale. This way, a very coarse dosage (net reference) or a refilling of the scalecontainer (gross reference) can be defined for example.5.5.12 DR 4 - Basis weight for the limit value 2The limit values can be defined in reference to the gross weight or the net weight ofthe scale. This way, a very coarse dosage (net reference) or a refilling of the scalecontainer (gross reference) can be defined for example.