No.Screen formparametersCycle pa‐rametersMeaning5 DX / DY / DZ S_SETV Distance (incremental) from the starting position to measuring point P1 of the measuringaxis (S_MA) 5)6 α S_STA1 Angle setpoint for "Align edge" or for "Align plane" around the 1st axis of the plane (for G17X) 9)7 β S_INCA Angle setpoint for "Align plane" around the 2nd axis of the plane (for G17 Y) 9)8 DFA S_FA Measurement path9 TSA S_TSA Safe areaMonitoring of the angle difference to the angle setpoint [degrees] 6)10 X / Y / Z S_MA Measuring axis, offset axis 7) (default=201)Val‐ues:UNITS: Number of the measuring axis1 = 1st axis of the plane (for G17 X)2 = 2nd axis of the plane (for G17 Y)3 = 3rd axis of the plane (for G17 Z)TENS: ReservedHUNDREDS: Number of the offset axis1 = 1st axis of the plane (for G17 X)2 = 2nd axis of the plane (for G17 Y)3 = 3rd axis of the plane (for G17 Z)11 +- S_MD Measuring direction of the measuring axis 8)Val‐ues:0 = Measuring direction is determined from the setpoint and the actual position ofthe measuring axis (compatibility)1 = Positive measuring direction2 = Negative measuring direction12 L2 S_ID For measuring variant "Align edge":Distance (incremental) between the measuring points P1 and P2 in the offset axis (value>0)For measuring variant "Align plane", the parameters listed below apply.13 L2 S_SETV0 Distance between the measuring points P1 and P2 in the 1st axis of the plane 10)14 S_SETV1 Distance between the measuring points P1 and P2 in the 2nd axis of the plane 11), 12)15 L3x S_SETV2 Distance between the measuring points P1 and P3 in the 1st axis of the plane 11)16 L3y S_SETV3 Distance between the measuring points P1 and P3 in the 2nd axis of the plane 10)17 Measure‐mentsS_NMSP Number of measurements at the same location 2) (default=1)18 S_EVNUM Date set, empirical value memory 2), 13)19 _DMODE Display modeVal‐ues:UNITS: Machining plane G17/G18/G190 = compatibility, the plane active before the cycle call remains active1 = G17 (only active in the cycle)2 = G18 (only active in the cycle)3 = G19 (only active in the cycle)20 _AMODE Reserved (alternative mode)1) All default values = 0 or marked as default=x2) Display depends on the general SD 54760 $SNS_MEA_FUNCTION_MASK_PIECE3) WO "fine" only if correction target is rotary axis and MD 52207 $MCS_AXIS_USAGE_ATTRIB[n] Bit6=1.If WO has not been set up in MDs, correction is according to WO "coarse".Parameter lists4.1 Overview of measuring cycle parametersMeasuring cyclesProgramming Manual, 12/2017, 6FC5398-4BP40-6BA1 315