3.3.5.3 Result parametersList of the result parametersThe measuring version "Radius between two edges" provides the following result parameters:Table 3-12 "Radius between two edges" result parametersParameter Description Unit_OVR [4] Actual value probe ball diameter mm_OVR [5] Difference probe ball diameter mm_OVR [8] Trigger point in minus direction, actual value of 1st axis ofthe planemm_OVR [10] Trigger point in plus direction, actual value of 1st axis of theplanemm_OVR [12] Trigger point in minus direction, actual value of 2nd axis ofthe planemm_OVR [14] Trigger point in plus direction, actual value of 2nd axis of theplanemm_OVR [9] Trigger point in minus direction, difference of 1st axis of theplanemm_OVR[11] Trigger point in plus direction, difference of 1st axis of theplanemm_OVR[13] Trigger point in minus direction, difference of 2nd axis of theplanemm_OVR[15] Trigger point in plus direction, difference of 2nd axis of theplanemm_OVR[20] Positional deviation of the 1st axis of the plane (probe skew) mm_OVR[21] Positional deviation of the 2nd axis of the plane (probe skew) mm_OVR[27] Work offset range mm_OVR[28] Safe area mm_OVI[2] Measuring cycle number -_OVI[5] Probe number -_OVI[9] Alarm number -The result parameters are written to, which correspond to the selected axis.3.3.6 Calibrate probe - calibrate on ball (CYCLE976)FunctionUsing this measuring method, a workpiece probe can be calibrated at any position in space.This has a special meaning in conjunction with swivel functions and transformations.Measuring variants3.3 Measure workpiece (milling)Measuring cycles124 Programming Manual, 12/2017, 6FC5398-4BP40-6BA1