08/2005 Starting Up HMI Embedded (IM2)4 Functions/Parameterization© Siemens AG, 2005. All rights reservedSINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition IM2/4-65Fig. 4-5 Dynamic user memory DRAMOperating instructions: See Section "Static user memory (SRAM), Detail view"Additional elements in DRAM memory allocation screen:Since the memory of some data areas is allocated to dynamic processes, theirmemory requirements vary. By selecting "Peak values=0" softkey, you can resetthe peak values of the currently displayed machine data to zero.Memory allocation: local user dataIn the DRAM main screen, click the "Local user data" area with the cursor and thenclick the "Details" vertical softkey to view and edit the memory settings of thefollowing machine data:MD 28020: MM_NUM_LUD_NAMES_TOTALMD 28040: MM_LUD_VALUES_MEMMemory allocation: reorganizationWhen you select the "REORG" area and click the "Details" vertical softkey, you candisplay and edit the memory settings in the following machine data:MD 28000: MM_REORG_LOG_FILE_MEMMD 28010: MM_NUM_REORG_LUD_MODULESMemory allocation: cyclesWhen you select the "Cycles" area and click the "Details" softkey, you can displayand edit the memory settings in the following machine data:MD 18170: MM_NUM_MAX_FUNC_NAMESMD 18170: MM_NUM_MAX_FUNC_PARAM