Controlling the safety functions5.4 Activating "SBC" via the Safe Brake AdapterSafety IntegratedFunction Manual, 07/2016, A5E03264275A 93WARNINGDanger to life if the maximum permissible cable length between the Safe Brake Adapterand the Control Interface Module is exceededIf the permissible cable length between the Safe Brake Adapter and the Control InterfaceModule is exceeded this can result in death or serious injury in the event of an error.• The maximum permissible cable length of 10 m between the 230 VAC Safe BrakeAdapter and the brake must be carefully maintained.• The cable must be routed according to ISO 13849-2, Table D.4.• It is recommended that the cable harness (length 4 m) with article number6SL3060-4DX04-0AA0 is used.Table 5- 26 Terminal strip X12, 230 VAC power supplyConnection Signal DescriptionX12.1 L Supply voltage: 230 VACCurrent consumption: 2 AProtection according to IEC 60269-1, operating class gGX12.2 NMax. connectable cross-section 2.5 mm2Table 5- 27 Terminal block X14, interface to the loadConnection Signal DescriptionX14.1 BR L Supply voltage: 230 VACCurrent consumption: 2 A, only for brakes with brake rectifierX14.2 BR NMax. connectable cross-section 2.5 mm2WARNINGDanger to life if the permissible cable length of the brake control is exceededIf the permissible cable length of the brake control is exceeded this can result in death orserious injury in the event of an error.• The maximum permissible cable length of 300 m between the 230 VAC Safe BrakeAdapter and the brake must be carefully maintained.• To accurately calculate the maximum cable length, see the SINAMICS Low VoltageConfiguration Manual on the customer DVD supplied with the device.