Chapter 4Technical SpecificationsRUGGEDCOM RX1500Installation Guide36 Gigabit Ethernet (1 Gbps) Optical SpecificationsOrderCode Mode ConnectorTypeCableType(μm)Tx λ(typ.)(nm)Tx min.(dBm)Tx max.(dBm)RxSensitivity(dBm)RxSaturation(dBm)Distance(typ.)(km)PowerBudget(dB)FX07 SM SC 9/125 1300 -5 0 -34 -3 50 29FX08 SM LC 9/125 1300 -5 0 -35 3 50 304FX08 SM LC 9/125 1300 -5 0 -35 3 50 30FX09 SM SC 9/125 1300 0 5 -37 0 90 37FX10 SM LC 9/125 1300 0 5 -37 0 90 374FX10 SM LC 9/125 1300 0 5 -37 0 90 37MTRJ 62.5/125 -19 12FX11 MMLC 50/1251300-22.5-14 -31 -14 28.5MTRJ 62.5/125 -19 124FX11 MMLC 50/1251300-22.5-14 -31 -14 28.5SFP Fast Ethernet TransceiversOrderCode Mode ConnectorTypeCableType(μm)Tx λ(typ.)(nm)Tx min(dBm)Tx max(dBm)RxSensitivity(dBm)RxSaturation(dBm)Distance(typ.)(km)PowerBudget(dB)62.5/125 -20 11FX51 MM LC50/1251310-23.5-14 -31 -14 27.5FX52 SM LC 9/125 1300 -15 -8 -31 -8 15 16FX53 SM LC 9/125 1300 -5 0 -34 0 40 29FX54 SM LC 9/125 1550 -5 0 -34 -10 80 29Section 4.5.3Gigabit Ethernet (1 Gbps) Optical SpecificationsNOTE• Maximum segment length is greatly dependent on factors such as fiber quality, and the numberof patches and splices. Consult a Siemens sales associate when determining maximum segmentdistances.• All optical power numbers are listed as dBm averages.• F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).Fixed Gigabit TransceiversOrderCode Mode ConnectorTypeCableType(μm)Tx λ(typ.)(nm)Tx min(dBm)Tx max(dBm)RxSensitivity(dBm)RxSaturation(dBm)Distance(typ.)(km)PowerBudget(dB)FG01 MM LC 50/125 850 -9 -2.5 -20 0 0.5 11FG02 SM SC 9/125 1310 -10 -3 -20 -3 10 10