P/N7121702 Rev. ABuilding TechnologiesFire Safety & Security ProductsIKP6-03LCD KeypadLCD-BedienteilClavier LCDTeclado LCDTastiera LCDTeclado numérico LCLCD-tastgruppeLCD-toetsenblokKlávesnice s LCD displejemKlawiatura LCDLCD codeklavierLCD TuştakımıEDMS: 009919_b_--_--English Installation InstructionBefore starting to install and work with this device, please read the SafetyInstructions.1 Scope of delivery:• IKP6-03 LCD keypad• Screws (a)• Plugs (b)• Tamper screw (c)Installation2 Removing the cover¾ Loose the retaining screw.¾ Lift off the cover from the base.3 Mounting the baseUse only the screws and plugs supplied.¾ Mount the base (inside up) to the wall using the build in spirit level (a).¾ If necessary adjust the distance to the wall of the back tamper contact (b)with the included tamper screw.4 Connecting upDisconnect the control panel from power (main and battery).¾ Connect the BUS from the control panel to the IKP6-03 unit on the terminalblocks, as described in the Installer Manual.¾ Reconnect the control panel to power: the display and the keys will light up ifcorrectly connected.If the lights are fast flashing, a connection failure had happen.Please recheck connection.5 Replacing the cover¾ Hook the cover onto the top of the base and press into position.¾ Screw in the retaining screws.FunctionsThe user communicates with the alarm system via the keypad. The keypaddisplays continuous information about the status of the alarm system and allowsthe user to operate the system in different modes, change settings and programusers' access codes.The keypad also keeps a log of events, which can be displayed subsequently ondemand when reviewing system activities and used to analyze systemperformance for diagnostic purposes.As an additional comfort feature a temperature indication is included in the display,which shows the temperature around the installed keypad.No. Name Description1 Display The LCD display shows all the informationrequired for trouble-free operation of the system.2 Function keys These keys are used to arm the system, entercommands to alter system settings, or scrollthrough the display.3 AlphanumericKkeysThese keys are used to enter codes, changedescriptions of zones, or for programming.Technical DataPower consumption 100 mA (backlight on) -40 mA (backlight off)Voltage 9 - 16 VBlue back light For key illuminationOperating temperature -10 - +50 °CDimensions 145 x 126 x 22 mmWeight ~300 grPower supply 12 V DC (Via E-BUS)LCD KP 2 x 16 charactersCable connection recommend to use shielded cable like Kat5.Max. bus length Tested up to 200mComplies with: EN 50130-4+A2, EN61000-6-3, EN55022 + A1+A2+Kl. B,EN50131-1, EN50131-3, Security Grade II, Environmental Class IICertified by:For more detailed instructions please refer to the manuals which can bedownloaded from internet: www.siemens.com/homesecurity2134 54xa 4xb 1xc