Siemens GAMMA instabus 5WG1125-1AB02 Operating And Mounting Instructions Manual
DE ENA5E03391100E_RS-AE Seite 1 von 2 page 1 of 2GAMMA instabusSpannungsversorgungN 125/02 (160 mA) 5WG1125-1AB02N 125/12 (320 mA) 5WG1125-1AB12N 125/22 (640 mA) 5WG1125-1AB22Power Supply UnitN 125/02 (160 mA) 5WG1125-1AB02N 125/12 (320 mA) 5WG1125-1AB12N 125/22 (640 mA) 5WG1125-1AB22Bedien- und MontageanleitungOperating and Mounting InstructionsStand: Juni 2020Issued: June 2020AnschlussbeispielApplication example8 9R ESETBetr ieb/ ONÜber last/ Over load5WG1125- 1AB22N+ -L+ -NLPEKNX +KNX -DC +DC -sProdukt- und FunktionsbeschreibungDie Spannungsversorgung erzeugt die für KNX erforderliche Sys-temspannung. Die Verbindung mit der Buslinie erfolgt über diefrontseitige Busklemme.Die integrierte Drossel verhindert den Kurzschluss der Datentele-gramme auf der Buslinie. Durch Betätigen des eingebauten Reset-Schalters werden die Busteilnehmer in den Grundzustand gesetzt(Betätigung > 20 s).Für jede Buslinie wird mindestens eine Spannungsversorgung be-nötigt, die in einem Verteiler montiert wird. In einer Buslinie sindmaximal zwei Spannungsversorgungen zulässig. Eine zweiteSpannungsversorgung ist nur erforderlich, wenn die Betriebs-spannung an einem Teilnehmer unter 21 V abfällt.Hinweis: Werden zwei Spannungsversorgungen parallel an einerBuslinie betrieben, so ist bei Aufleuchten der Überlastanzeige aneiner oder beiden Busspannungsversorgungen die Buskonfigura-tion so zu ändern, dass keine Überlastanzeige mehr erfolgt.Die Leitungslänge zwischen zwei parallel betriebenen Span-nungsversorgungen ist nicht vorgegeben.Werden mehr als 30 Busteilnehmer z.B. in einem Verteiler mitkurzen Leitungsdistanzen (z.B. 10 m) eingebaut, soll die Span-nungsversorgung in der Nähe dieser Busteilnehmer angeordnetwerden. Die Entfernung zwischen der Spannungsversorgung undeinem Busgerät darf max. 350 m sein.Die Spannungsversorgung hat eine Spannungs- und Stromrege-lung und ist damit kurzschlussfest. Kurze Netzunterbrechungenüberbrückt sie mit ca. 200 ms Pufferzeit.Aus Gründen der Versorgungssicherheit wird empfohlen, für denNetzanschluss der Spannungsversorgung einen eigenen, separatabgesicherten Stromkreis zu verwenden.Bei den Spannungsversorgungen kann die Ausgangsspannungunverdrosselt DC 24 V an einem zusätzlichen Klemmenpaar(gelb/weiß) frontseitig abgegriffen werden. Diese Ausgangsspan-nung kann z.B. zur Versorgung einer zusätzlichen Linie über eineseparate Drossel genutzt werden.Weitere Informationenhttp://www.siemens.de/gamma-tdTechnische DatenEingangsspannung• Bemessungsspannungen: AC 120-230 V, 50 ... 60 HzDC 220 VBemessungsleistungsaufnahmeca. 24 VAAusgangsspannung• Bemessungsspannung DC 24 V• Schutzkleinspannung (SELV)• zulässiger Bereich DC 21 ... 30 VAusgangsstrom• Bemessungsstrom 160 mA (N 125/02),320 mA (N 125/12),640 mA (N 125/22)• Kurzschlussstrom:begrenzt auf 1,0 A (N 125/02, N 125/12), 1,5 A (N 125/22)Pufferzeitbei Ausfall der Eingangsspannung ca. 200 msbei BemessungsstromAnschlüsse• Netzspannung, Steckklemmen schraubenlos:Abisolierlänge 10...11 mmEs sind folgende Leiterquerschnitte zulässig:- 0,5...2,5 mm² eindrähtig- 0,5...2,5 mm² feindrähtig unbehandelt- 0,5...2,5 mm² mehrdrähtig unbehandelt- AWG 20 (0,75 mm²) - AWG 12 (3,3 mm²)eindrähtig, feindrähtig• Buslinie:Druckkontakte auf Datenschiene,Busklemme (schwarz/rot), schraubenlos0,6 ... 0,8 mm eindrähtig• Ausgangsspannung (unverdrosselt):Kleinspannungsklemme (gelb/weiß), schraubenlos0,6 ... 0,8 mm eindrähtigMechanische Daten• Abmessungen: Reiheneinbaugerät im N-Maß,Breite 4 TE (1 TE = 18 mm)• Gewicht: ca. 260 gElektrische Sicherheit• Schutzart (nach EN 60529): IP 20Umweltbedingungen• Umgebungstemperatur im Betrieb: - 5 ... + 45 C• Lagertemperatur: - 25 ... + 70 C• rel. Feuchte (nicht kondensierend): 5 % bis 93 %Product and Applications DescriptionThe power supply unit provides the system power necessary forKNX. The connection to the bus line is established via the bus con-nection block (red/black) located on the front side.The integrated choke prevents the data telegrams from short-cir-cuiting on the bus line. When the built-in reset switch is operated(operation > 20s), the bus devices are returned to their initialstate.For each bus line, at least one power supply unit is needed. Up totwo power supply units may be attached to a single bus line. Asecond unit is not required unless the supply voltage at a bus de-vice is less than 21 V.Note: If two power supply units are operated in parallel on onebus line and if the overload LED is lit on one or both power sup-plies, then the bus configuration must be changed until the over-load display disappears.The cable length between the two power supply units operatedin parallel is not prescribed.When more than 30 bus devices are installed in short bus cabledistance (e.g. 10 m), e.g. in distribution boards, the power supplyunit should be arranged near these bus devices. The distance be-tween power supply unit and any of its bus devices must not ex-ceed 350 m.The power supply unit has a voltage and current regulation andis therefore short-circuit proof. Short power failures can bebridged with a backup interval of approximately 200 ms.To ensure an uninterrupted power supply a separate circuit withsafety separation should be used for the power supply unit powersupply line.The power supply units can supply DC 24 V power from an addi-tional pair of terminals (yellow/white). This output voltage can beused to power e.g. an additional line via a separate choke.Additional Informationhttp://www.siemens.com/gamma-tdTechnical specificationsInput voltage• rated voltage: AC 120-230 V, 50 ... 60 HzDC 220 VRated power intakeapprox. 24 VAOutput voltage• rated voltage: DC 24 V• safety extra low voltage (SELV)• permissible range: DC 21 ... 30 VOutput current• rated current 160 mA (N 125/02),320 mA (N 125/12),640 mA (N 125/22)• short-circuit current:limited to 1.0 A (N 125/02, N 125/12), 1.5 A (N 125/22)Backup intervalon input voltage failure: approx. 200 ms at rated currentConnections• mains connection, screwless plug-in terminals:strip insulation for 10 ... 11 mmpermissible conductor types/cross sections:- 0.5...2.5 mm² single core- 0.5...2.5 mm² plain flexible conductor- 0.5...2.5 mm² stranded conductor- AWG 20 (0.75 mm²) – AWG 12 (3.3 mm²) solid, stranded• bus line:pressure contacts on data rail,screwless extra low voltage terminal (red/black) 0.6 ... 0.8 mm• output voltage (no choke):screwless extra low voltage terminal (yellow/white) 0.6 ... 0.8 mmPhysical specifications• dimensions: N-system DIN-rail mounted device,width: 4 SU (1 SU = 18 mm)• weight: approx. 260 gElectrical safety• protection (according to EN 60529): IP 20Environmental specifications• ambient temperature operating: - 5 ... + 45 C• storage temperature: - 25 ... + 70 C• relative humidity (non-condensing): 5 % to 93 % |
Related manuals for Siemens GAMMA instabus 5WG1125-1AB02
Siemens GAMMA N 125/02 Operating And Mounting Instructions Manual
Siemens SIPLUS PSU Operating Instructions Manual
Siemens SITRANS I300 Operating Instructions Manual
Siemens SIDOOR ATD400S Operating Instructions Manual
Siemens SITOP Power 10 Operating Instructions Manual
Siemens SITOP Series Operating Instructions Manual
Siemens SITOP series Operating Instructions Manual
Siemens 4AV Series Operating Instructions Manual
Siemens SITOP modular 20 Operating Instructions Manual
Siemens SIMATIC PS307 Operating Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved