Sealey WB10 Instructions Manual
6.5. operation alu4 – clamp and Stick weight6.5.1. switch on machine and press P4 until Alu4 balance modeis selected on display.6.5.2. mount the wheel on the shaft and lock.6.5.3. input wheel parameter.6.5.4. lower down the wheel guard and the wheel will automaticallyspin.6.5.5. At the end of the spin the machine will automatically display6.5.6. imbalance values.6.5.7. Lift up guard and manually rotate the wheel until all inner/outerimbalance position led’s are lit.6.5.8. Position required balance weights and fix at the 12 o’clockposition. use foot brake to hold wheel in position.6.5.9. Once weights are fixed, lower down the guard and allow thetest to start again.6.5.10. if the test results are correct, remove wheel from shaft.6.5.11. if the test results are incorrect, then repeat the process untilcorrect.6.6. operation alu5 – clamp and Stick weights6.6.1. Switch on machine and press P4 until ALU5 balance mode isselected on display.6.6.2. mount the wheel on the shaft and lock.6.6.3. input wheel parameter.6.6.4. lower down the wheel guard and the wheel will automaticallyspin.6.6.5. At the end of the spin the machine will automatically displayimbalance values.6.6.6. Lift up guard and manually rotate the wheel until all inner/outerimbalance position led’s are lit.6.6.7. Position required balance weights and fix at the 12 o’clockposition. use foot brake to hold wheel in position.6.6.8. Once weights are fixed, lower down the guard and allowthe test to start again.6.6.9. if the test results are correct, remove wheel from shaft.6.6.10. if the test results are incorrect, then repeat the process untilcorrect.6.7. operation alS1 – Smart aluminium balance modeThe ASL1 Smart Balance Mode allows the operator the choose position of where to stick the weights. The greater the distance betweentwo weights positioning the more precise the balance results achieved.6.7.1. switch on machine and press P4 until Als1 balance mode is selected on display.6.7.2. Pull out the distance measuring Arm and rest it against the inner rim face and hold until machine has registered measurement witha double beep. the left display screen will show di 1 and the right display screen will show distance value XXX. continue to move theDistance Measuring Arm to the outer rim face for weight positioning. Hold it until machine automatically registered measurement witha double beep, then return arm back to home position. the left display screen will show di 2 and the right display screen will showdistance value XXX6.7.3. lower down the wheel guard and the wheel will automatically spin.6.7.4. At the end of the spin the machine will automatically display imbalance values.6.7.5. lift up guard and manually rotate the wheel until all inner imbalance position led’s are lit.6.7.6. Fix weight at the 12 o’clock position. Use foot brake to hold wheel in position. This is just for the first distance 1 (di 1) measurement.6.7.7. Press P2 for distance 2 (di 2) positioning. display will show “src” left screen and “on” right screen.6.7.8. manually rotate the wheel until all outer imbalance position led’s are lit. use foot brake to hold wheel in position.6.7.9. Position stick on weights to distance measuring Arm.6.7.10. Pull out distance measuring Arm until the right display screen show Pos, plus a double beep is heard.6.7.11. fix the stick on weights to inner wheel rim and return distance measuring Arm to home position.6.7.12. once weights are fixed, lower down the guard and allow the test to start again.6.7.13. if the test results are correct, remove wheel from shaft.6.7.14. if the test results are incorrect, then repeat the process until correct.6.8. operation alS2 – Smart aluminium balance mode6.8.1. switch on machine and press P4 until Als2 balance mode is selected on display.6.8.2. Pull out the distance measuring Arm and rest it against the inner rim face and hold until machine has registered measurement witha double beep. the left display screen will show di 1 and the right display screen will show distance value XXX. continue to move theDistance Measuring Arm to the outer rim face for weight positioning. Hold it until machine automatically registered measurement witha double beep, then return arm back to home position. the left display screen will show di 2 and the right display screen will showdistance value XXX.6.8.3. lower down the wheel guard and the wheel will automatically spin.6.8.4. At the end of the spin the machine will automatically display imbalance values.6.8.5. lift up guard and manually rotate the wheel until all left imbalance position led’s are lit.6.8.6. Press P2 for distance 1 (di 1) positioning. display will show “Ac9” left screen and “on” right screen.6.8.7. Position stick on weights to distance measuring Arm.6.8.8. Pull out distance measuring Arm until the left display screen show’s dil, plus a double beep is heard.6.8.9. fix the stick on weights to inner wheel rim and return distance measuring Arm to home position.6.8.10. manually rotate the wheel until all right imbalance position led’s are lit.6.8.11. Position stick on weights to distance measuring Arm.6.8.12. Pull out distance measuring Arm until the right display screen show’s Pos, plus a double beep is heard.WB10 | Issue 1 05/02/18Original Language Version© Jack sealey limited |
Related manuals for Sealey WB10
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved