Sealey MM18 Manual
Also see for MM18: Instruction manual
pOCKET MULTIMETERmODEL NO: MM18Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,and properly maintained, give you years of trouble free performance.IMpORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USETHE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/ORPERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.1. SAFETY1.1. pERSONAL pRECAUTIONS9 When using this multimeter, please observe all normal safety rules concerning:9 Protection against the dangers of electrical current.9 Protection of the meter against misuse.9 Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must be replacedwith genuine Sealey leads with the same electrical ratings. Failure to do so will invalidate the warranty.8 DO NOT use leads if damaged or if the wires are bared in any way.1.2. GENERAL SAFETY INSTRUCTIONS9 Familiarise yourself with the application and limitations of the multimeter as well as the potential hazards.IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.▲ USE EXTREME CAUTION when working with high voltages.8 DO NOT use the meter if it is damaged. Before you use it inspect the case. Pay particular attention to the insulation surrounding theconnectors.9 Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace damaged test leads beforeyou use the meter.8 DO NOT use the meter if it operates abnormally. Protection may be impaired. When in doubt have the meter inspected by your Sealeystockist.8 DO NOT operate the meter where explosive gas, vapour or dust is present.8 DO NOT apply more than the rated voltage, as marked on the meter, between the probes or between any probe and earthground.9 Before use verify the meter’s operation by measuring a known voltage.9 When measuring current, turn off circuit power before connecting the meter in the circuit. Remember to place the meter in series with thecircuit. WARNING! Use caution when working with voltage above 30V ac rms, 42V peak, or 60V dc. Such voltages pose a shock hazard.9 When using the probes keep your fingers behind the finger guards.9 When making connections, connect the black test lead before you connect the red test lead. When you disconnect the test leads,disconnect the red one first.9 Remove the test leads from the circuit under test before you open the back cover.8 DO NOT operate the meter with the back cover removed or loosened.9 To avoid false readings, which could lead to possible electric shock or personal injury, replace the button cells as soon as the low batteryindicator ( ) appears.8 DO NOT touch any naked conductor with your hand or skin, to avoid electric shock, DO NOT ground yourself whilst using the meter.9 When a probe is connected to a dangerous live potential, it must be noted that this potential can occur at the other probe.NOTE: CAT II measurement category is for measurements performed on circuits directly connected to low voltage installations.(Examples are measurements on household appliances, portable tools and similar equipment.) DO NOT use the meter for measurementswithin measurement Categories III and IV.9 Disconnect circuit power and discharge all capacitors before testing resistance, diode or continuity.9 Use the proper function for your measurements.9 Before measuring current, check the meter’s fuse and turn off power to the circuit before connecting the meter to the circuit.9 Before moving the function switch or rotating the range switch, disconnect the test leads from the circuit under test.9 The user shall ensure that test probes are correctly selected in order to prevent danger. Probes shall be selected to ensure that adequatebarriers guard against inadvertent hand contact with live conductors under test and that probes have minimal exposed probe tips. Wherethere is a risk of the probe tip short circuiting with other live conductors under test, it is recommended that the exposed tip length shall notexceed 4mm.NOTE:The warnings, cautions and instructions referred to in this manual cannot cover all possible conditions and situations that mayoccur. It must be understood that common sense and caution are factors which cannot be built into this product, but must be appliedby the operator.SRefer toinstructionmanualWarning!ElectricityOriginal Language Version© Jack Sealey Limited mm18 | Issue:3 (H,F) 07/12/18 |
Related manuals for Sealey MM18
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved