Sealey MM24 Instructions Manual
Quality tradesman's multimeter with easy to read 26mm LCD display. Features protective rubber boot, probe storage and integral stand.Supplied with probe test leads.1.1 PERSONAL PRECAUTIONS When using this multimeter, please observe all normal safety rules concerning:Protection against the dangers of electrical current.Protection of the meter against misuse. Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must be replaced withgenuine Sealey leads with the same electrical ratings. Failure to do so will invalidate the warranty. DO NOT use leads if damaged or if the wires are bared in any way.1.2 GENERAL SAFETY INSTRUCTIONS Familiarise yourself with the application and limitations of the multimeter as well as the potential hazards.IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN. When the meter is connected to a circuit, do not touch unused meter terminals. When the magnitude of the value to be measured is unknown, set the range selector to the highest value available. Before commencing testing, follow instructions below and select the correct input sockets, function and range on the multimeter. Before rotating the rotary switch to change functions, disconnect the test leads from the circuit under test. Take care when working with voltages above 60V DC or 30V AC rms. Keep fingers behind the probe barriers whilst measuring. DO NOT test voltages above 600V - the circuitry of the multimeter may be destroyed. WARNING! NEVER connect the multimeter to a voltage source / live circuit when the rotary switch is set to any other function apart fromVoltage testing WARNING! NEVER perform resistance, transistor, diode or continuity measurements on live circuits. DO NOT use the multimeter in a potentually explosive atmosphere. Ensure that the rear cover is in place and fastened before using the multimeter. Before attempting to insert transistors for testing, ensure that test leads have been disconnected. Components should not be connected to the transistor socket or capacitor socket when taking voltage measurements with the test leads. If any abnormal readings are observed, the multimeter must be checked out by an authorised technician. When not in use, store the multimeter carefully in a safe, dry, childproof location out of direct sunlight. Storage temperature range -10°C to 50°C.InSTruCTIonS For:DIGITAL MULTIMETER7 FUNCTIONMoDEL no: MM24Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions andproperly maintained, give you years of trouble free performance.1. SAFETY INSTRUCTIONSIMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCTCORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILLINVALIDATE THE WARRANTY. PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.2. FEATURESFeatures:1. LCD Display2. on/off Button3. Hold Button4. rotary Switch5. 10A Socket6. mA Socket7. CoM Socket8. V/Ω Socket9. Transistor Testing Socket12 34576982Function Measures Red LeadConnection Input LimitsV DC Voltage V/Ω 600V DCV ~ AC Voltage V/Ω 600V AC (sine)A DC Current mA or 10A 10A DCA ~ AC Current mA or 10A 10A ACΩ resistance V/Ω 20M ΩBATT Battery Checker mA 9.0V(200) Audible Continuity V/Ω -(2k) Diode Verification Mode V/Ω -hFE Transistor Verification Mode mA -Original Language Version MM24 Issue no: 2 - 02/07/10 |
Related manuals for Sealey MM24
Sealey MM20.V2 Instructions Manual
Sealey MM104 Instructions Manual
Sealey MM402 Instructions Manual
Sealey MM18 Instruction Manual
Sealey MM302.V2 Instructions Manual
Sealey TM104 Instructions Manual
Sealey TM103 Instructions Manual
Sealey TM105 Instructions Manual
Sealey TM101 Instructions Manual
Sealey Professional MM20 Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved