Sealey AK466D Quick Start Manual
OIL DRAINER 230VMODEL NO: AK466DThank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,and properly maintained, give you years of trouble free performance.IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USETHE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/ORPERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.1. SAFETY1.1. ELECTRICAL SAFETY WARNING! It is the user’s responsibility to check the following:Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs andall electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electricalproducts. You may obtain an RCD by contacting your local Sealey stockist.If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (PortableAppliance Test) tested.Electrical safety information, it is important that the following information is read and understood.Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with thecorrect fuse - see fuse rating in these instructions.8 DO NOT pull or carry the appliance by the power cable.8 DO NOT pull the plug from the socket by the cable.8 DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired oris replaced immediately by a qualified electrician.This product is supplied without a plug and requires a BS1363/A 13 Amp 3 pin plug to be fitted.If the cable or plug is damaged during use, switch off the electricity supply and remove from use.Ensure that repairs are carried out by a qualified electrician.Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.b) Connect the BROWN live wire to the live terminal ‘L’.c) Connect the BLUE neutral wire to the neutral terminal ‘N’.Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.Sealey recommend that repairs are carried out by a qualified electrician.Cable extension reels. When a cable extension real is used it should be fully unwound before connection. Acable reel with an RCD fitted is recommended since any product which is plugged into the cable reel will be protected. The section of thecable on the cable reel is important. We recommend that at least 1.5mm2 section cable but to be absolutely sure that the capacity of thecable reel is suitable for this product and for others that may be used in the other output sockets, we recommend the use of 2.5mm²section cable.1.2. GENERAL SAFETY WARNING! Disconnect the pump from the mains power before changing accessories, servicing or performing any maintenance.9 Keep the pump clean and maintain it in good condition (use an authorised service agent).9 Replace or repair damaged parts. Use genuine parts only. Non authorised parts may be dangerous and will invalidate the warranty.9 Locate pump in adequate working area for its function, keep area clean & tidy and free from unrelated materials. Ensure there is adequatelighting.9 Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery, and contain and/ or tie back long hair.9 Sump oil temperature should be 50°C or above for extraction. Ensure you wear appropriate protective clothing and gloves.9 Keep all non essential persons away from the working area.9 Check pump connections and fitting before use. When the pump is turned on check that there are no leaks.9 Ensure the collection tank reservoir capacity exceeds waste oil amount to be collected.9 Avoid unintentional starting of the pump and ensure end nozzle is correctly inserted into the dip stick access hole before operating.8 DO NOT use the pump for any purpose other than for which it is designed.8 DO NOT use to extract diesel, petrol or flammable liquids.8 DO NOT operate the pump if any parts are damaged or missing as this may cause failure or possible personal injury.8 DO NOT pull or yank any pipes or hose, and do not attempt to move the pump by pulling the hose or cable.8 DO NOT leave the pump operating whilst unattended.8 DO NOT direct the nozzle at yourself or others.8 DO NOT pull the cord from the power supply. WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment.9 Dispose of waste oil in accordance with local authority regulations.VAK466D | Issue:4 (H,F) 07/03/18Original Language Version© Jack Sealey LimitedRefer toinstructionmanualWearprotectiveglovesWear eyeprotection WearprotectiveclothingRecommended fuse rating13Amp |
Related manuals for Sealey AK466D
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved