Copyright© 1995-2012 SAMSUNG. All rights reserved. 7-9Adjustment7-7 CCD defect ADJ1. Save the applicable adjustment file to the memory card.2. After inserting the memory card containing the program file, turn on the power of the camera.3. The adjustment will automatically start.q Check the set reference level, exposure time and loop, and execute the Defective Pixel calibration.w Refer to the specification (Maximum number of defective cells) and execute the check.e Refer to the CARD WRITE information to write the number of defective cells to the data file.4. When the adjustment is completed, the camera will automatically be turned off.On the memory card, open and check if a CSV file was generated from the adjustment.■ Calibrate the Defective pixel of CMOS for each camera.7-8 OIS centering ADJ1. Save OIS .hex file and script file on memory card.2. Install memory card with a program file and then, turn the camera on.3. Adjustment is made automatically.OIS module will be operated left/right/up/down 2-3 times.4. When the adjustment is completed, the camera will be off automatically.On the memory card, open and check if a CSV file was generated from the adjustment.■ Process to check if OIS performs well or not.CAUTION!Put your camera, face up, on a steady surface such as a table or anything solid that won’t move.Don’t put your camera on a highly unstable surface. Also don’t put your camera down or hold it.The noise may significantly affect degrading the Gyro Sensor and Hall Sensor performance. PreviousNext |