Self-test mode of wired remote controllerUse of self-test mode0Please enter your PASSWORDService modeService modeReset All Service ModePower Master ResetODU K3 ResetField Setting ValueSelf-Test ModeIndoor Unit Option1. If you want to use the various additional functions for your Wired Remote Controller, press the and buttons at thesame time for more than 3 seconds.f The password entry screen appears.2. Enter the password, “0202,” and then press the button.f The settings screen for installation/service mode appears.3. Select Self-Test Mode in Service Mode.4. Self-Test Mode consists of Self-Test Mode Display that shows operation value satus and menus that can turn eachcomponent on or off.Self-Test ModeSelf-Test Mode DisplayWater PumpBooster HeaterDHW Valve (3 Way valve)Zone#1 ValveBack Up Heater1 + Water PumpBack Up Heater2 + Water PumpBack Up BoilerZone#2 ValveMixing Valve< OFF >< OFF >< OFF >< OFF >< OFF >< OFF >< OFF >< OFF >< OFF >Self-Test Mode DisplayWater Inlet Temp.: -00.0ঐ to 000.0ঐWater Outlet Temp.: -00.0ঐ to 000.0ঐBackup Heater Outlet Temp: -00.0ঐ to 000.0ঐMixing valve Outlet Temp.: -00.0ঐ to 000.0ঐTank Temp: -00.0ঐ to 000.0ঐIndoor Ambient Temp.: -00.0ঐ to 000.0ঐIndoor Ambient Temp. (Zone2): -00.0ঐ to 000.0ঐFlow Temp. Sensor #1(Zone1): -00.0ঐ to 000.0ঐFlow Temp. Sensor #2(Zone2): -00.0ঐ to 000.0ঐTermostat #1(Zone #1): Coo/HeatTermostat #2(Zone #2): Coo/HeatSolar Panel On/Off: On/OffSelf-Test Mode Display29ENGLISH