InstallationInstallationEnglish20STEP 3 Connect the electrical wiringFirst, read through the “Electrical requirements” section, and follow these steps.3-wire systemABECDA. External ground connectorB. Neutral grounding wire (white)C. Center silver-colored terminal blockscrewD. Neutral wire (white or center wire)E. 3/4” (1.9 cm) UL-listed strain relief1. Loosen or remove the center terminalblock.2. Connect the neutral wire (white orcenter wire) of the power cable to thecenter, silver-colored terminal screw ofthe terminal block. Tighten the screws.3. Connect the other wires to outerterminal block screws. Tighten thescrews.4. Tighten the strain relief screws.5. Insert the terminal block cover into therear panel of the dryer. Then, secure thecover with a hold-down screw.CAUTION• To convert from the 4-wire systemto 3-wire system, connect the groundstrap to the terminal block support toground the dryer frame to the neutralconductor.• Ring-type terminals are recommended.If using strap terminals, make sure theyare tightened.DV7450M-03170Z-00_EN.indd 20 2016-12-26 9:06:43