Samsung DV 60M9900 Series Service Manual
39 _ Troubleshooting■ Centrifugal Switch (Motor)■ Thermistor238.23 Ω @ 25°C 77■ GAS MODELRadiant Sensor(10RS)• Resistance value < 1 Ω• If resistance is replace Radiant sensor120VIgniter(101D)• Resistance value 40~400 Ω• If resistance is replace Igniter 120V 4.5AThermostat (60T21 Hi-Limit)230F-50F• Resistance value < 1 Ω• If resistance is replace Thermostat120V 20A (60T2)2.88Ω betweenPin# 3 and 43.5Ω betweenPin# 4 and 5Gas valve (25M01A)• Valve 1-2: Resistance value approx. 1365 Ω• Valve 1-3: Resistance value approx. 560 Ω• Valve 4-5: Resistance value approx. 1325 Ω• Valve 6-7: Resistance value approx. 1000 Ω• If resistance is infinite, replace valve.“This document can not be used without Samsung's authorization” |