26Time and polarities of the ALARM/CONTROL connectorTerminal name Active Time RemarksAlarm input 100 ms or more N.O.: L activeN.O.: H activeAlarm reset input 100 ms or more L activeEmergency recording input 100 ms or more L activeOutage detection input 5 s or more L activeExternal recording modeswitching input100 ms or more L activeNetwork error output At an error occurrence until the period selected for "Error out-put duration" has passed*L activeHDD error output At an error occurrence until the period selected for "Error out-put duration" has passed*L activeCamera error output At an error occurrence until the period selected for "Error out-put duration" has passed* or the camera resetL activeRecording error output At an error occurrence until the period selected for "Error out-put duration" has passed*L activeRecorder error output At an error occurrence until the period selected for "Error out-put duration" has passed*L activeOutage processing end out-put10 s or more H activeAlarm output The set time on the setup menu L activeTime adjustment I/O Input: 100 ms or moreOutput: The set time on the setup menuInput/Output: L active* The error output duration is configured on the "Advanced setup" menu - the "Maintenance" page - "System setup" of the setupmenu. (☞ Operating Instructions (PDF))Note:• During "L active (Low active)", the logic will be implemented when the voltage level of signal is low.• During "H active (High active)", the logic will be implemented when the voltage level of signal is high.3 Connections (continued)