11 Connections With PS*Data EquipmentCommunication setup is required for PS • Data equipment as follows.• Protocol selection: PS • DATA• Unit Address: Set an address unique in the chain.• Baud rate, data bit length, parity check, stop bit: Set the same values as other equipment using in the chain.Recommended video multiplexers are Panasonic’s WJ-FS series or similar models having specifications as follows.• Switching recognition signal is located within 8H prior to the end of vertical blanking.• The camera switching allows to be slowed than 4/60 seconds.SIGNAL GNDALARMSERIESRECORDTIMEADJUSTREMOTEMODEDATARS-232CVIDEOOUTINOUTINAUDIO MONITOR OUT(PLAY)CAMERASW OUTGGGJOG-CLICKJOG-LEFTJOG-RIGHTALARM SEARCHSTEPREW/FFSTOP/SETUPPLAYRECOUTPLAY OUTREC OUTAUTO OFF OUTDISK END OUTINOUTINRECALLOUTRECOVER OUTRESET ININPOWERONOFFONOFFPOWERPOWERONOFFALARMData Multiplex Unit WJ-MP204ALARMSUSPENDSystem ControllerPOWERONOFFONCameraDATA PortDATA Port Multi ScreenOutData Multiplex UnitVideo MultiplexerCamera InCamera OutVideo MonitorSet the termination toON when the unit isplaced at the end of thechain, or to OFF otherthan the end position.System Controller with PS•DataCapabilityDATA PortDigital Disk RecorderMonitor OutVideo InVideo InRecOutPlayInVideo InDATA PortMODECAM SWInCamera SWOut(EXT REC)If the cable is locally procured, make sure it is datagrade cable suitable for RS-485 communication. A 2-wire twisted pair shielded cable, BELDEN 9406 orequivalent should be used. Pin assignments and dataflow are shown below.1616No. No.Name Data Flow1 1GND –2 2RX(B) WJ-HD100 ← WV-CU3603 3RX(A) WJ-HD100 ← WV-CU3604 4TX(B) WJ-HD100 ← WV-CU3605 5TX(A) WJ-HD100 ← WV-CU3606 6GND –ControllerendIntelligent Security & Fire