When repeaters are not used:When repeaters are used:10.2.1 Registering a repeater to the mainmonitor1 : From the top menu, touch ®® [Register/Cancel] ® [Register] ®[Repeater] ® select the number of the repeater to beregistered.2 Registering the first repeater:Go to step 3.Registering the second repeater:Select the connection method according to how youwant to use the repeater. (® page 39)R If [Connected together] is selected, go to step 5.3 Touch [Next].4 Select the device that you want the repeater toconnect to.R After this, use the repeater and complete thefollowing steps within about 2 minutes.5 : Connect power to the repeater that you wantto register, and then press PROGRAM (A) for about3 seconds.R The ID indicator (B) flashes green.ABR The indicator lights when the registration iscompleted.(Depending on the signal status, the indicatormay not light in green. In this case, see therepeater’s Getting Started.)6 : Press .Note:R When using devices in separate buildings or overlong distances, cut outs and image distortions maynot be improved even if a repeater is used.10.3 Cancelling sub monitors,cameras, and repeaters– Cancelling can only be performed on the mainmonitor.1 From the top menu, touch ® ®[Register/Cancel] ® [Cancel] ® select the type ofdevice to be cancelled.2 Select the device to cancel from the displayed list.R Cancelling repeaters:When 2 repeaters are connected together, onlythe farthest from the main monitor can becancelled.3 Confirm the message and then touch [Yes].R A beep sounds and "Cancel completed" isdisplayed.4 To end the operation, press .Important:R To prevent incorrect operations, remove thebatteries from cancelled sub monitors.4010. General information