Panasonic VL-SWD501AZ Installation Manual
Also see for VL-SWD501AZ: Quick start guide
Installation GuideNote to the installer■ Before attempting to connect or operate this product, please read the label on the rear ofthe main monitor.■ Please read this guide carefully, and install the product safely and correctly by followingthe instructions. Carefully read the information found in the section titled "For your safety"in particular.■ Only use attachments/accessories specified by the manufacturer.■ The installation shall be carried out in accordance with all applicable installation rules.■ Panasonic assumes no responsibility for injuries or property damage resulting from failuresarising out of improper installation or operation inconsistent with this guide. Additionally,any resulting malfunction will not be covered under the warranty.■ After installation, make sure to leave this guide with the customer.For the Installation of door stationand main monitor station• VL-V554BX is a surface mount type, VL-V554UBXis a flush mount type.For your safetyTo prevent severe injury and loss of life/property, read this section carefully before using theproduct to ensure proper and safe operation of your product.WARNINGPreventing fire, electric shock and short circuits● Leave installation work to the dealer.Installation work requires technique and experiences. Failure to observe this maycause fire, electric shock, injury, or damage to the product. Consult the dealer.● Electrical connection work should be performed by certified personnel only. Certificationis required for performing electrical connection work. Consult your dealer.● Use only the specified power supply unit and AC cable.● Do not attempt to disassemble or modify this product. Contact an authorised servicecentre for repairs.● Never install wiring during a lightning storm.● Do not connect non-specified devices.● Do not connect a power cable to a terminal that is not specified in this guide.● When opening holes in walls for installation or wiring, or when securing the powercable, make sure you do not damage existing wiring and ductwork.● Do not make any wiring connections when the power supply is turned on.● Do not use the supplied power supply unit for outdoor installations (it is for indoor useonly).● Do not install the main monitor and power supply unit in the following places:- Places where the main monitor and power supply unit may be splashed with water orchemicals.- Places where there is a high concentration of dust, or high humidity.● Do not perform any actions (such as fabricating, twisting, stretching, bundling, forciblybending, damaging, altering, exposing to heat sources, or placing heavy objects on thepower cable) that may damage the power cable. Using the product with a damagedpower cable may cause electric shock, short circuits, or fire. Contact an authorisedservice centre for repairs.● When existing chime wires are used, it is possible that they contain AC voltage.Contact an authorised service centre.● Do not install or use the product in health care facilities if any regulations posted inthe area instruct you not to do so. Hospitals or health care facilities may be usingequipment that could be sensitive to external RF (radio frequency) energy.● Do not install or use this product near automatically controlled devices such asautomatic doors and fire alarms. Radio waves emitted from this product may causesuch devices to malfunction, resulting in an accident.Preventing accidents and injuriesCAUTION● If the wiring is underground, do not make any connections underground.● If the wiring is underground, use a protection tube.● If the wiring is outdoors, use a protection tube or a surge protector.● Install the product securely adhering to the instructions in this guide to prevent it fromfalling off the wall. Avoid installing onto low-strength walls, such as gypsum board, ALC(autoclaved lightweight concrete), concrete block, or veneer (less than 18 mm thick) walls.Preventing electric shockPreventing injury1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan© Panasonic System Networks Co., Ltd. 2014PNQW4430ZA C0814MM0VL-V554BX/VL-V554UBXVL-MWD501BXDoor station Main monitor stationDoor station is described as "doorphone"and Main monitor station is described as"main monitor" in this guide.Model No. VL-SWD501AZVL-SWD501UAZWireless Video Intercom SystemSupplied accessories for installation■ For the doorphoneMountingbase × 1(AZ only)Flushmountingbox × 1(UAZ only)Screw × 4 (Used wheninstalling the doorphone)(AZ : 4 mm x 12 mm)(UAZ : 4 mm x 25 mm)Name plate × 2(incl. 1 spare) Hex wrench × 1■ For the main monitorMountingbracket × 1 Cable binder × 1 Screw × 2(4 mm x 16 mm)■ Power supply unit and related itemsPower supplyunit × 1(Part No. VL-PS241) AC cable × 1Cable binder × 1Screw × 2(4 mm x 40 mm)To avoid malfunction or communication disturbances, do not install the doorphone or the mainmonitor in the following locations:- Places where vibration or any other kind of impact occurs.- Places where echoing is frequent.- Places near a high concentration of dust, hydrogen sulphide, ammonia, sulphur, or noxiousfumes.■ For the doorphone● If a strong light is shining on the doorphone, the visitor’s face may not be distinguishable. Donot place the doorphone in the following locations:- Where most of the background is the sky.- Where the background is a white wall, and direct sunlight will reflect off it.- Where direct sunlight will shine on the doorphone.● Do not place the doorphone in locations where echoing occurs, as this will cause thedoorphone to beep frequently.● Dust protection/water protection is IP54.Only when installation work specified in this guide is properly performed and appropriate waterprotection treatment is performed.● Make sure the rear of the doorphone is not subject to water.● Depending on the installation location, condensation may form on the doorphone’s lens cover.This may cause images to become obscured. Condensation will dissipate as the temperaturerises.■ For the main monitor● Install the main monitor away from electronic appliances such as TVs, radios, personalcomputers, air conditioners, boiler control panels with intercom, home security equipment,wireless devices, or digital cordless phones.● Do not install the main monitor in places where it will be affected by extremely high-frequencyradio waves (near broadcasting antennas etc.). This may cause the display to flicker or aninterrupting noise to occur.● Leave at least 20 cm of space above, below, and to the left and right sides of the mainmonitor. Do not install on a wall that is deeply recessed.● Do not install the main monitor inside a wall.● Be sure to install the main monitor more than 5 m away from the doorphone.● The product operates in the frequency range of 1.88 GHz to 1.90 GHz, and the RFtransmission power is 250 mW (max.). Refer to the "For best performance" section in theOperating Instructions.● In areas surrounded by a high electrical field, disturbances may occur in the main monitor’simage or sound.Important:● You will need the following additional items to install and configure the doorphoneand the main monitor.[Locally procured]- DC cable and wires (for doorphone and other connections):Prepare a cable and wires of the appropriate specification. ( "Wire type and length")Note:● The illustrations in the supplied manual(s) may vary slightly from the actual product.Precautions for installationWiring schematic diagramSet up correctly according to the following wiring schematic diagram and "Wire type and length".● For information, such as order numbers, about optional devices that can be connected to, refer to the "Additional/replacement accessories" section in the Operating Instructions.ブプMAIN MONITORDOORPHONE 1DOORPHONE 2POWER SUPPLY UNITConnection device for option output (A contact)NP: Non-polarisedPowersupplyPowersupply12 V AC/DC12 V AC/DCElectric lockElectric lock24 V DCWire type and lengthWiring runWire type*1Diameter Length (Max.)Main monitor –Doorphone Aø 0.65 mm 22 AWG 100 mø 1.0 mm 18 AWG 130 mø 0.5 mm CAT 5 50 mMain monitor –Power supply unit Bø 0.65 mm 22 AWG 10 mø 1.0 mm 18 AWG 20 mDoorphone –Electric lock *2 C ø 0.5 mm - ø 1.2 mm(24 AWG - 17 AWG)According to specifi-cation of connecteddevice.Main monitor –Connection device for optionoutput (A contact)*2D ø 0.5 mm - ø 1.2 mm(24 AWG - 17 AWG)According to specifi-cation of connecteddevice.*1 Type: Single-pair cable with outer sheath (jacket)Conductor: Copper solid● A certified power supply wiring has to be used with this equipment. The relevant nationalinstallation and/or equipment regulations shall be considered. A certified power supply wiringnot lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.*2 When using an electric lock or a connection device for option output (A contact), select a devicethat meets the following guidelines:● Electric lock connection terminal (S1/S2):- N/O dry closure contact- 12 V AC/DC, less than 1 A● Connection device for option output (A contact) terminal (OUT1/OUT2):- 24 V AC/DC, less than 0.3 A (minimum contact: 5 V DC 1 mA)ACCDBNPNPNPNPNPNP& screw × 2(3.8 mm x 20 mm) |
Related manuals for Panasonic VL-SWD501AZ
Panasonic VL-SWD501 Installation Manual
Panasonic VL-SWD501EX Installation Manual
Panasonic VL-MWD501 Installation Manual
Panasonic VL-SV71 Installation Manual
Panasonic VL-SV70 Installation Manual
Panasonic VL-SV74 Installation Manual
Panasonic VL-SW102BX Installation Manual
Panasonic VL-SW250BX Installation Manual
Panasonic VL-V900 Installation Manual
Panasonic VL-V591 Installation Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved