8.2. Initialization Pulse Adjust1. Input a white signal to plasma video input.Aging pattern : 02. Set the picture adjustment items as follows.· Picture menu : Standard· Color temperature : Normal· Picture : 25· Aspect : Full3. Connect Oscilloscope to TPSC1 (T1) and check for less than 40μ Sec.4. Connect Oscilloscope to TPSC1 (T2) and adjust VR6602 for 160 ± 10μ Sec.Test point Volume LevelT1 TPSC1 (SC) Fixed Less than 40μ SecT2 TPSS1 (SS) VR6602 (SC) 160 ± 10μ Sec8.3. P.C.B. (Printed Circuit Board) Remove8.3.1. Caution1. To remove P.C.B., wait 1 minute after power was off for discharge from electrolysis capacitors.8.3.2. Quick adjustment after P.C.B. RemoveP.C.B. Name Test Point Voltage Volume RemarksP Board Vsus TPVSUS Vsus ± 2V VR251 (P) *SC Board Vad TPVAD -90V ± 1V VR6600 (SC)Vscn TPVSCN Vad + 140V ± 4V FixedVset TPVSET 240V ± 7V FixedSS Board Ve TPVE Ve ± 1V VR6600 (SC) *Vda TPVDA 72V ± 1V, -3V FixedD, DS Board White balance and Sub brightness for NTSC, PAL, HD, PC and 625i signalsDN Board Set Market Select Number to correct destination by Ms mode (See chap. 9.1.4)*See the Panel label.Caution:Absolutely do not reduce Vsus below Ve not to damage the P.C.B.26TH-65PF9BK / TH-65PF9EK