223. Remove the Cabinet assy from the Plasma panel section.8.2.16. Remove the Contact metal bottom1. Remove the screws (×8 ) and remove the Contactmetal bottom.8.2.17. Remove the C1-Board1. Disconnect the flexible cables (CB1, CB2, CB3 and CB4).2. Disconnect the flexible cable (C10).3. Remove the screws (×4 ) and remove the C1-Board.8.2.18. Remove the C2-Board1. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).2. Disconnect the flexible cables (C20 and C21).3. Disconnect the connector (C25).4. Remove the screws (×4 ) and remove the C2-Board.8.2.19. Replace the Plasma panelCaution:Place the Plasma panel on a flat surface of a table(covered by a soft cloth) and a cushion.A new Plasma panel itself without Contact metals is fragile.To avoid the damage to new Plasma panel, carry a newPlasma panel taking hold of the Contact metal bottom.1. Place a carton box packed a new Plasma panel on theflat surface of the work bench.2. Open a box and without taking a new Plasma panel.3. Attach the Cabinet assy and each P.C.Board and so on,to the new Plasma panel.