Panasonic SW-200 Series Instruction Manual
Optical Touch SwitchSW-200 SeriesSPECIFICATIONS5WARNINGMOUNTING AND NAMES OF COMPONENTS3EnclosureBaseModel SW-211OutputOutput operationShort-circuit protectionResponse timeSwitchable either Light-ON or Dark-ONIncorporated (Automatic reset)100ms or less when an object is detected, 50ms or less when an object is not detectedOperation indicator 1. Orange LED (lights up when the output is ON) 2. Orange LED flashes abnormally (when there are objects being detected for a long time)Power indicatorCableAmbient temperatureAmbient humidityMaterial Enclosure: PC Protection Cover: nylon (PA66) Base: PBT0.2mm 2 , 5-core cabtyre cable, standard length: 2mInfrared LED (modulated) Emission wavelength: 950nm500m/s 2 acceleration (50G approx.) in X, Y and Z directions for three times each (deenergized)20MΩ, or more, with 500V DC megger between all supply terminals connected together and enclosure1,000V AC for one min. between all supply terminals connected together and enclosureIP65(IEC)Green LED (lights up when the power is ON)Supply voltageCurrent consumption10V to 30V DC ± 10% / Ripple (P-P) 10% or less40mA or lessSemiconductor photo-MOS output●Maximum load current: 100mA or less●Applied voltage: 30V DC or less●Residual voltage: 1.5V or less (at 100mA load current)ProtectionAmbient illuminanceVoltage withstandabilityInsulation resistanceVibration resistanceShock resistanceEnvironmental resistoince-25°C to +55°C (no dew condensation or icing allowed), Storage: -30°C to +70°C35%RH to 85%RH, Storage: 35%RH to 85%RH10Hz to 500Hz frequency, 3mm double amplitude (MAX.20G) in X, Y and Z directions for 2 hours each (deenergized)Emitting elementNet weight: 200g approx. Gross weight: 250g approx.Cable extensionWeightExtension up to total 100m is possible with 0.3mm 2 , or more, cableAccessories rubber gasket: 1pcs, positioning washer: 1pcs, lock washer: 1pcs, mounting nut: 1pcs, protection cover: 1pcsOPERATION DESCRIPTION6Operation indicator(orange LED)Output operationLights offLights onOFFONDark OnLight OnMode A t≥3 mint<3 minMode B Light OnDark OnONOFFLights onLights offOutput operationOperation indicator(orange LED)t<3 min t≥3 min4 I/O CIRCUIT DIAGRAMMode Status Output operation Operation indicatorMode ALight On ON Always ONDark On (t<3 min)Dark On (t≥3 min)Return to Light OnOFF Lights offON FlashesON Always ONMode Status Output operation Operation indicatorMode BLight On OFF Lights offDark On (t<3 min)Dark On (t≥3 min)Return to Light OnON Always ONOFF FlashesOFF Lights off30.5+0.5017.5 +0.50INSTRUCTIONMANUAL● Never use this product as a sensing device for personnel protection.● In case of using sensing devices for personnel protection, useproducts which meet standards, such as OSHA, ANSI or IEC etc.,for personnel protection applicable in each region or country.Common cathode circuit diagram(Note): The pink line hanging in the air indicates model A, the pink line connecting with 0V indicates model B.[Black] OUT1100mA max.10V to 30V DC±10%Internal circuitLoad[Brown] +V[Blue] 0V[Pink] A/B switchingExternal input circuitExternal inputZD : Surge absorption zener diodeZ DZ D[White] OUT2Main circuit(Note): The pink line hanging in the air indicates model A, the pink line connecting with 0V indicates model B.Common anode circuit diagram[Black] OUT110V to 30V DC±10%[Brown] +V[White] OUT2[Pink] A/B switching[Blue] 0VExternal input circuitExternal inputZD : Surge absorption zener diodeZ DZ DInternal circuitLoad100mA max.Main circuitThank you very much for purchasing Panasonic products.Please read this Instruction Manual carefully and thoroughly forthe correct and optimum use of this product.Kindly keep this manual in a convenient place for quick reference.OPERATION INDICATOR2Operation indicator (orange)Power indicator(green)● The orange LED lights up whenoutput is ON● The orange LED flashes whenthere are objects being detectedfor a long timeCAUTIONS1This product has been developed/produced for industrial use only.Make sure to carry out wiring in the power supply off condition.Take care that wrong wiring will damage the sensor.Verify that the supply voltage variation is within the rating.If power is supplied from a commercial switching regulator, ensure thatthe frame ground (F.G.) terminal of the equipment is connected to anactual ground. F. G.In case noise generating equipment (switching regulator, invertermotor, etc.) is used in the vicinity of this product, connect the frameground (F.G.) terminal of the equipment to an actual ground.Do not run the wires together with high-voltage lines or power linesor put them in the same raceway. This can cause malfunction dueto induction.Do not use during the initial transient time (150ms) after the powersupply is switched on.Take care that the sensor is not directly exposed to fluorescentlight from a rapid-starter lamp or a high-frequency light device orsunlight etc., as it may affect the sensing performance.Extension up to total 100m is possible with 0.3mm2, or more, cable.Make sure that the stress by forcible bend or pulling is not applieddirectly to the sensor cable joint.This sensor is suitable for indoor use only.Do not use this product in places having excessive vapor, dust,dirt, etc. or where it may come in direct contact with water, orcorrosive gas.Take care that the product does not come in contact with water, oil,grease, or organic solvents, such as thinner, etc.When the match cable is connected with the sensor, the tighteningtorque should be 0.5N·m or less.M30 male thread andNPSM1/2" female threadRubber gasket(accessory)Lock washer(accessory)Protection cover(accessory)Mounting nut(accessory) Positioning washer(accessory)(Note):● The positioning washer and lock washer can be used interchangeably● The tightening torque should be 180N·m or less● When the positioning washer is not used, the diameter of themounting hole is φ30.5 mm● When the positioning washer is used, the dimension of the process hole forthe mounting plate (more than 2mm thick) is shown as below (unit: mm)+0.505 +0.20Incandescent light: 3,000 x at the light-receiving face Sunlight: 120,000 x at the light-receiving face7 INTENDED PRODUCTS FOR CE MARKINGThe models listed under “ SPECIFICATIONS ”come with CE Marking.As for all other models, please contact our office.5Panasonic Marketing Europe GmbH Panasonic Testing CenterWinsbergring 15 , 22525 Hamburg , Germany |
Related manuals for Panasonic SW-200 Series
Panasonic SW-100 Series Instruction Manual
Panasonic SG-P Series Instruction Manual
Panasonic SG-B2 Series Instruction Manual
Panasonic SW-100 Instruction Manual
Panasonic AJ8 Series Instructions Manual
Panasonic SG-P Series Quick Instruction Manual
Panasonic SG-P Series Quick Instruction Manual
Panasonic SW-101 Instruction Manual
Panasonic SW-111 Instruction Manual
Panasonic GA-AS12TPoE+ Series Instruction Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved