Panasonic SG-P Series Quick Instruction Manual
Also see for SG-P Series: Quick instruction manualInstruction manual
QUICK INSTRUCTION MANUALNon-Contact Safety Door SwitchSG-P SeriesCMJE-SGP No.0077-95VThank you very much for purchasing Panasonic products.Please read this Instruction Manual carefully and thoroughly for the correctand optimum use of this product. Kindly keep this manual in a convenientplace for quick reference.This document provides a brief summary of mounting, wiring, and other related information.When using the product, refer to the SG-P Series Instruction Manual in addition to this manual.1 SAFETY CAUTIONS Always observeThis section explains important rules that must be observed to prevent human injury and property damage.Ŷ 7KHKD]DUGVWKDWPD\RFFXULIWKHSURGXFWLVXVHGLQFRUUHFWO\DUHGHVFULEHGDQGFODVVL¿HGE\OHYHORIKDUPWARNING Risk of death or serious injury.CAUTION Risk of minor injury or property damage.WARNINGMachine designer, installer, employer and operator• The machine designer, installer, employer and operator are solely responsible toensure that all applicable legal requirements relating to the installation and the useLQDQ\DSSOLFDWLRQDUHVDWLV¿HGDQGDOOLQVWUXFWLRQVIRULQVWDOODWLRQDQGPDLQWHQDQFHcontained in the instruction manual are followed.• Whether this device functions as intended to and systems including this devicecomply with safety regulations depends on the appropriateness of the application,installation, maintenance and operation. The machine designer, installer, employerand operator are solely responsible for these items.Engineer• The engineer would be a person who is appropriately educated, has widespreadknowledge and experience, and can solve various problems which may ariseduring work, such as a machine designer, installer or employer etc.Operator• The operator should read this instruction manual thoroughly, understand its con-tents, and perform operations following the procedures described in this manualfor the correct operation of this device.• In case this device does not perform properly, the operator should report this to theperson in charge and stop the machine operation immediately. The machine mustQRWEHRSHUDWHGXQWLOFRUUHFWSHUIRUPDQFHRIWKLVGHYLFHKDVEHHQFRQ¿UPHGOperating environment• Do not use this device outdoors.• Do not use this device in an explosion-proof area.• Do not install this device in the following places:1) Areas with high humidity where condensation is likely to occur2) Areas exposed to corrosive or explosive gases3) Areas exposed to contact with water4) Areas exposed to too much steam or dust• Do not use this device near equipment that emits strong electromagnetic waves.Machine in which this device is installed• Do not install this device with a machine whose operation cannot be stoppedimmediately in the middle of an operation cycle by an emergency stop equipment.• This device starts the performance after approximately 2 seconds from the powerON.Have the control system started to function with this timing.• Do not use the device improperly or do not invalidate the settings after installingthe device. Otherwise, the safety functions of the apparatus which uses this devicemay not work properly, resulting in death or serious injury.• Do not install the switch body of this device on a movable door.• When installing this device, always consider the time required to ensure a safe stateand provide a distance equal to or longer than the correctly calculated safety distancebetween the apparatus which uses this device and the dangerous parts of the machine.• &RQ¿UPWKDWWKHUHVSRQVHWLPHRIWKHHQWLUHPDFKLQHLVOHVVWKDQWKHFDOFXODWHGvalue before designing the equipment.Wiring• Be sure to carry out the wiring in the power supply OFF condition.• All electrical wiring should conform to the regional electrical regulations and laws.The wiring should be done by engineer(s) having the special electrical knowledge.• After completing wiring, check the wiring state before supplying power.• Do not wire the controller in parallel with a high-voltage line or power line or use thesame conduit as these lines. Doing so may result in malfunctioning due to induction.• Do not apply stress such as excessive bending or pulling to a cable or theextracted part of a cable. In particular, when the temperature is low, cable materialsharden, and when the temperature is high, the materials soften, and so take carethat cables may break if they are subject to stress such as bending or pulling whenthe temperature is low or high.• When connecting multiple switch bodies, arrange their layout so that the total cablelength is 100 m or less. Furthermore, determine the distance between the switchbodies so that the maximum cable length between them is 20 m or less.• When using only one switch body, arrange its layout so that the maximum cable length is 20 m or less.• When extending the cable of this device, use 0.3 mm 2 or larger cable.• When wiring, make sure that liquid such as water or oil does not intrude from the end of the cable.Maintenance• When replacement parts are required, always use only genuine suppliedreplacement parts. Using substitute parts from another manufacturer may causethe device not to detect objects, resulting in death or serious injury.• The periodical inspection of this device must be performed by an engineer having the special knowledge.• After maintenance or adjustment, and before starting operation, test this deviceIROORZLQJWKHSURFHGXUHVSHFL¿HGLQ³ 8 Maintenance”.• Clean this device with a clean cloth. Do not use any volatile chemicals.Others• 1HYHUPRGLI\WKLVGHYLFH0RGL¿FDWLRQPD\FDXVHWKHGHYLFHQRWWRGHWHFWREMHFWVresulting in death or serious injury.CAUTION6SHFL¿FDWLRQV• This product has been developed / produced for industrial use only.• 'RQRWXVHWKLVSURGXFWRXWVLGHWKHUDQJHRIWKHVSHFL¿FDWLRQV5LVNRIDQDFFLGHQWDQGSURGXFWGDPDJH• There is also a risk of a noticeable reduction of service life.• Use this device by installing suitable protection equipment as a countermeasurefor failure, damage, or malfunction of this device.• Before using this device, check whether the device performs properly with theIXQFWLRQVDQGFDSDELOLWLHVDVSHUWKHGHVLJQVSHFL¿FDWLRQV• Note that this device may be damaged if it is subject to a strong shock (if it isGURSSHGRQWRWKHÀRRUIRUH[DPSOH • Do not use the device near an apparatus that generates magnetic fields.2WKHUZLVHWKHRSHUDWLQJGLVWDQFHPD\EHDႇHFWHG• Do not apply an excessive shock to the safety switch when opening or closing the door.• Use of this device under the following conditions or environments is not presupposed.Please consult us if there is no other choice but to use this device in such an environment.1) Operating this device under conditions or environments not described in this manual.2) 8VLQJWKLVGHYLFHLQWKHIROORZLQJ¿HOGVQXFOHDUSRZHUFRQWUROUDLOURDGDLUFUDIWauto mobiles, combustion facilities, medical systems, aerospace development, etc.Power supply• 9HULI\WKDWWKHVXSSO\YROWDJHÀXFWXDWLRQVDUHZLWKLQWKHUDWLQJ• When using a commercial switching regulator for the power supply, be sure toground the frame ground (F.G.) terminal of the power supply.• When using the device, avoid the transient state that occurs when the power supply is turned ON.• When connecting multiple devices together, connect all the devices to the same power supply.Other precautions• Never attempt to disassemble, repair, or modify the product.• When the product becomes unusable or unneeded, dispose of the productproperly as industrial waste by abiding by the applicable law in the country.2 CONTENTS OF PACKAGEDevice : Switch body, Actuator 1 unitQuick Instruction Manual (Japanese / English, Chinese) 1 PC each3 PRODUCT CONFIGURATIONƔ 7KLVGHYLFHLVFRQ¿JXUHGRQDVZLWFKERG\DQGDQDFWXDWRUƔ This device is available as the 6*3ƑƑ0 standard units and as the 6*3ƑƑ6sub units. For one 6*3ƑƑ0 standard unit, up to a maximum of 29 6*3ƑƑ6sub units can be operated by connecting them in a cascade connection.Ɣ )RUGHWDLOVRQ0RGHO1RUHIHUWR³10 Model No.”.Possible to connect a maximum of 29 units.SafetycontrollerPower supply unitStandard6*3ƑƑ-MSub 6*3ƑƑ-SActuatorSwitch bodySub 6*3ƑƑ-SSub 6*3ƑƑ-SƔ Note that the 6*3ƑƑ6 sub unit cannot be used alone. When using a singledevice, use the 6*3ƑƑ0 standard unit. When connecting multiple devicestogether, use the 6*3ƑƑ6 sub unit for the second unit onwards.Ɣ The 6*3ƑƑ0 standard unit can be connected with all 6*3ƑƑ6 sub units.Ɣ Be sure to use this device together with a safety device such as a safety controller.4 NAME AND FUNCTION OF THE DEVICEƔ Compact typeName FunctionIndicatorLights green When the actuator is detectedLights red When the actuator is not detectedBlinks red •Lockout state, error occurrence• When the teaching sequence was incorrect (only when using high code models)Blinks green • When multiple units are connected, the actuator is not detected by other switch bodies.• When multiple units are connected, an error has occurred in other switch bodies.Lights yellow (Green, red,simultaneous lighting) After the power ON, self-diagnosisAlternately blinking red and yellow(lights red and blinks green) When an actuator not paired is detected (only when using high code models)Actuator detection surface When the actuator is brought near to the surface, the switch body detects the actuator.Switch body detection surface When the actuator is brought near to the switch body, the switch body detects the actuator.Switch body detection surface |
Related manuals for Panasonic SG-P Series
Panasonic SG-P Series Quick Instruction Manual
Panasonic SG-P Series Instruction Manual
Panasonic SG-B2 Series Instruction Manual
Panasonic SW-200 Series Instruction Manual
Panasonic SW-100 Series Instruction Manual
Panasonic AJ8 Series Instructions Manual
Panasonic GA-AS12TPoE+ Series Instruction Manual
Panasonic SG-C1-21-EG Instruction Manual
Panasonic SW-100 Instruction Manual
Panasonic SW-101 Instruction Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved