11 Self-Diagnostic Function11.1. Self-diagnostic displayThis unit is equipped with a self-diagnostic display function which, will display an error code corresponding to the problem occuring.Use this function when performing checking maintenance on the unit.11.2. How to enter the Self-Diagnostic Function11.3. Cassette Mechanism Test (For error code H01, H02, H03, F01)1. Press “TAPE, DECK 1/2” to select Deck 2.2. Load a cassette tape with the erasure prevention tab, remove from left side only and close the cassette holder.3. Press “FAST FORWARD MEMORY” (Tape will be stop after 2 seconds)4. Load a cassette tape with the erasure prevention tab, remove from right side only and close the cassette holder.5. Press “REVERSE FM MODE/BP” (Tape will be stop after 2 seconds)6. Load a pre-recorded tape with both side record tabs intact and close the cassette holder.7. Press “PLAY/TUNE/TIME ADJ UP” (After TPS function, tape will stop automatically)8. Press “REC/STOP” (Tape will not move)9. Press “STOP/TUNE MODE” to indicate Error code.· If several problem exist, error code will change each time when “n /STOP” is pressed.(e.g. H01 → H03 → F01 .....etc.)10. Press “TAPE, DECK 1/2” to select Deck 1.11. Repeat step 2 to 9 to test Deck 1. (Tape Deck 1 will not check H02 because of no recording function)11.4. CD Mechanism Test (F15, F26, F16, F17, F27, F28, F29, F30, H15 &H16)1. Press (set to CD Mode) on main unit.2. Press “CD DIRECT PLAY (1)” and button on main unit.41SA-AK230PL