1404.9.4. Exception HandlerOn the Switch Tools Configuration Menu, pressing "x" opens the Exception Handler screen,as shown in Fig. 4-9-6. On this screen, you can configure the exception handling operations.Fig. 4-9-6 Exception HandlerScreen DescriptionShows the status of exception handler.The factory default setting is "Disabled."Enabled Exception handler is enabled.Exception HandlerDisabled Exception handler is disabled.Shows the method of exception handler.Debug Message When the Switching Hub detects exception handler, a debugmessage is displayed on the console screen.Exception Handler ModeSystem Reboot When the Switching Hub detects exception handler, the systemautomatically starts rebooting.Available commands are listed below.Enable/disable exception handler.XPress "X." The command prompt changes to "Enable or Disable Exception Handler (E/D)>." Press"E" to enable the function. Press "D" to disable it.Set the method of exception handler.MPress "M." The command prompt changes to "Select Exception Handler Mode (M/R)>." Press"M" to display a debug message. Press "R" to reboot.Q Return to the previous menu.PN28160/PN28160A Local Management SystemSwitch Tools Configuration -> Exception HandlerException Handler: DisabledException Handler Mode: Debug Message-------------------------------- -----------------------------------Enable/Disable E[x]ception HandlerSet Exception Handler [M]ode[Q]uit to previous menuCommand>Enter the character in square brackets to select option