Panasonic PD50 Installation Manual
Also see for PD50: Brochure & specs
GNDF.E.24VOUT3OUT2Confirm the followings before connecting the positive terminalof the power supply to ground.ANPD050-02ANPD050-05ANPD050-10ANPD050-15ANPD050-20ANPD050-25ANPD050-30Product No. Install.Dist.Unit:mm2×1.630×2510×85×415×1220×1625×20001040305070154555306580105X/YInput COM(±)InputSystem ConfigurationPower I/O CableInput and Output CircuitsInstallation Space Between the Multiple Units Installation AnglePower SuppliesWiringWiringBefore Turning on the PD50Note on Connecting the Positive Terminal of the Power Supply to GroundPrevent electrostatic buildup.Keep the cable connecting between the product and the Operation Unit andthe input/output signal cables to/from the product at least 100mm away fromother cables such as power transmission cable or electric power cable andkeep the signal cables as short as possible.Lighting equipment for image processing system generates signal of extremelyhigh level due to high frequency lighting. If you use external lighting, arrange the wiringof power transmission and signal cables carefully.Confirm that the power wiring and input/output wiring are correct.When turning the PD50 on again, wait at least 10 seconds.(The device may malfunction.)Note on Connecting to the PD502Installing the Main Unit3Turn the product off before attaching the wires, mounting or removing the product.<Input> Install another power supply for PD50 Main Unit. Do not connect the positive terminalof the power supply to ground (See [1] in the figure below).Should the positive terminal of the power supply be connected to ground, do not usethe FG terminal of an external device such as PLC, etc. because the SG terminalof the PD 50 may be connected to ground via the FG terminal.(See [2] in the figure below)InstallationdistanceInstallationdistanceOutput COM(±)OutputPhotoMosPD50Main UnitMounting BracketOperation UnitFinder UnitOptional Cable(for RS232C/operation unit)Optional Cable(for operation unit)Power I/O CableUSB Cable(AB TYPE)Commercially available8A2 L07 7000 2Powersupply PD50PLC, etcPCSGSGSG USBSGFGFGFE(FG)RS232CRS232CSGOuter shellOuter shell+24 V0 V+24 V0 VGroundGroundGround[1] [2]Use a rated voltage of 21.6 to 26.4 V DC for the mains power supply.Use a power supply with more than 1A current capacity.Use an earth for grounding and avoid sharing an earth with other equipment.Ensure that the earth source is as close to the product as possible and keep the lengthof the earth cable short.For some computers, the SG terminal of RS232C port and the outer shell ofthe connector have already been connected.The +24 V terminal of the PD50 is not insulated.If a computer is connected, the SG terminal of the PD50 and the FG terminal ofan external device such as PLC, etc. will be connected and a short-circuit conditionwill occur, resulting in damaging the internal circuit ground.If the camera capturesthe mirror reflection lightfrom the shiny object tobe measured, tilt the camera.Keep the enough space to prevent the lights emittedfrom each unit from interfering with each other(see the table below).ViewrangeMake sure to fit noise suppressor or other noise killers to the load sourcewhen direct inductive loads (motors or relays) are connected to the external devicewhich is connected to the Main Unit.ObjectDescriptionInputPOWERCOM for input (IN)(±)Trigger inputSwitch to TEACHING modeInput type number (IN)3 bit (binary input)(Input 0 to 6: Specify the desired product type number)COM for output (OUT)(±)READY outputAlarm outputOutput signal for successful read--24 V DC for power supplyFunctional EarthCableWhiteRedGrayOrangeYellowPurpleWhite/BlackBlackWhite/YellowBlueShieldSignalIN-COMTRIGGERTEACHTYPE1TYPE2TYPE3OUT-COMREADYALARMOUTPUT1OUTPUT2OUTPUT324 VGNDF.E.White/BrownWhite/RedWhite/OrangeBrownOutputGND (0 VDC) for power supplyEnsure that the mains power supplied to the product comes from a source other thana motor power supply and that a protection circuit (fuse, etc.) is installed.Do not apply load to the connector joints.Main UnitOption CableMounting BracketOperation UnitFinder UnitPD50 seriesANE2803 (for RS232C)ANE2813 (for Operation Unit)ANE8870ANE11ANE12ANE2823 (for RS232C/Operation Unit)Optional Cable(for RS232C)Power supplyRated load voltage : 5 - 24 V DCMax. applied voltage : 30 V DC Max. load current : 24 mARated input voltage : 12 - 24 V DCGeneral CautionsSafety PrecautionsDo not connect Ethernet to the connector on the Operation Unit for connectingthe Optional Cable or the port for connecting the Operation Unit.This may cause product damage.Only use Optional Cables, Operation Unit, and Finder Unit specifiedby Matsushita Electric Works, Ltd. Any damage faults or defects arising fromthe use of products not specified by Matsushita Electric Works, Ltd are not coveredby product warranty.Always take precautions to ensure the overall safety of your system, so that the whole systemremains safe in the event of failure of this product or other external factor.Do not use this product in areas with inflammable gas. It could lead to an explosion.Exposing this product to excessive heat or open flames could cause damage to the lithiumbattery or other electronic parts.To prevent abnormal exothermic heat or smoke generation, use this product at the values lessthan the maximum of the characteristics and performance that are assured in thesespecifications.Do not dismantle or remodel the product. It could lead to abnormal exothermic heat or smokegeneration.Do not touch the terminal while turning on electricity. It could lead to an electric shock.Use the external devices to function the emergency stop and interlock circuit.Connect the wires or connectors securely. The loose connection might cause abnormalexothermic heat or smoke generation.Do not allow foreign matters such as liquid, flammable materials, metals to go into the inside ofthe product. It might cause exothermic heat or smoke generation.Do not undertake construction (such as connection and disconnection) while the power supplyis on.Do not bend the cables forcibly, place a heavy object on them or bring them close to a thermalappliance. This might result in an electric shock and smoke coming from the product.The protection structure (IP67) for the Main Unit functions with the USB cable removedand water-proof cap attached. If the protection structure got wet or dusty underany other condition, malfunctions, damages and defects may occur.Environmental PrecautionsLocations where oil or chemicals may splash the productLocations subject to strong vibration or impactLocations subject to direct sunlightLocations near the devices that generate large switching surges,high-voltage wires (devices), power-driven lines (devices), and transmitting devices,such as radios (at least 100mm)Avoid installing the PD50 in the following locations:Locations with ambient temperature outside the range of 0 ℃ to +40 ℃(without icing and dew condensation)Ambient humidity outside the range of 35 to 85% RH(without icing and dew condensation at 25℃)Locations where airborne dust, oily smoke, conductive dust, or corrosive orflammable gas is presentInstallationManual2D Code Reading Sensor PD50To ensure that you install this product correctly, read this installation manual carefullybefore installation. Once you finish installing the product, keep this manual in a safe placefor future reference.Observe the followings when installing or using the product.Precautions for Installation1 |
Related manuals for Panasonic PD50
Panasonic MA2Z748 Installation Manual
Panasonic MA3X153A Installation Manual
Panasonic AJ-YA901 Installation Manual
Panasonic AY-PB2002 Installation Manual
Panasonic KX-TGA20 Installation Manual
Panasonic KX-HNS107 Installation Manual
Panasonic KX-HNS101 Installation Manual
Panasonic KX-HNS104 Installation Manual
Panasonic WV-TW310L Installation Manual
Panasonic KX-HNS101 Installation Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved