LC2HPart names1. Front reset buttonThis button resets the count value. Itdoes not work when the lock switch isON. Be aware that battery life willdecrease if this switch is used frequently.2. Lock switch (Refer to chart onright.)Disable the front reset button.Note) Turn ON at the LCD side (reset disabled) andOFF at the terminal block side (reset enabled).3. Count speed switch (Refer to charton right.)Use this switch to switch the count speedbetween 30 Hz and 2 kHz. (On the non-voltage and voltage input types, 30 Hz ison the LCD side and 2 kHz is on theterminal block side. Fixed at 30 Hz forfree voltage input type.)Note) You must press the front reset button when youchange the count speed switch setting.Confirm, however, that the Lock Switch is OFF(front switches operable).Notes) 1. ❇Default setting when shipped.2. Make the switch setting before installing to panel.Non-voltage input/voltage input Free voltage inputLock switch(Unit display 1)Count speedswitch(Unit display 2)Count speed switchLock switchRESETCOUNTERLC2HFront reset button(Terminal block side)(LCD side)OFF❇ON(Terminal block side)(LCD side)2k Hz30Hz❇—(Fixed at 30 Hz)Dimensions1. Panel mounting type• External dimensions1) One-touch installation typemm inchGeneral tolerance: ±1.0 ±.039• Panel installation diagramNote) When installing to a 4.5 mm .177 inch thick panel, remove the rubber spacerfirst.When installing the one-touch installation type model, make surethat the installation spring does not pinch the rubber gasket.To prevent the installation springfrom pinching the rubber gasket:1. Set the rubber gasket on bothends of the installation spring(left and right).2. Confirm that the installationspring is not pinching the rubbergasket, and then insert and fix theinstallation spring in place from therear of the timer unit.44.81.76454.42.1425.197(44)(1.732)10.4.4097.27622.866481.89024.945Reset buttonCOUNTERLC2HRESETRubber spacerPanel (1 to 4.5mm.039 to .177inchthickness)All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.