3.3 Data Management66 Programming GuideFirmware StatusIndicates the current firmware status of the correspondingpage. There are 3 kinds of status indications:• Main Operation Mode: Active firmware data on startupunder normal operation.• OLD: Firmware data uploaded to the card before thefirmware data in the "Main Operation Mode" status wasuploaded.• NEW: Firmware data uploaded to the card after thefirmware data in the "Main Operation Mode" status wasuploaded.NoteThe status indications "OLD" and "NEW" are irrelevant tothe version of the firmware data.Display onlyStartup PageIndicates (with an "x" sign) the active page on startup.Generally, the startup page is the firmware data whose statusis "Main Operation Mode".The exception is when the card undergoes a reboot after afirmware data upload operation; in this case, the card startsup with the page in the "NEW" status. This is for the purposesof confirming the result of the upload operation. If you rebootagain, the card starts up with the page in the "Main OperationMode" status.To set the updated page as the active page on startup, youmust change its firmware status to "Main Operation Mode".Display onlyOperationSpecifies whether to set the page (selected with theparameter Select Page) as the active page on startup ("MainOperation Mode"), or delete the page ("Empty")."Empty" is an option provided for engineer use only.Not applicable Empty,Main Operation ModeSelect PageSpecifies the target page of the operation selected with theparameter Operation.Not applicable Page-0,Page-1Parameter & Description Default Value Range