1.3 Specifications1.3.1 General DescriptionControl Bus Original bus (16-bit, 8 MHz, 10 megabytes per second)Communication Bus H.100 bus conformity (1024 time slots)Switching Non-blockingPower Input KX-NCP500 100 V AC to 130 V AC; 1.0 A/200 V AC to 240 V AC; 0.6 A; 50Hz/60 HzKX-NCP1000 100 V AC to 130 V AC; 1.3 A/200 V AC to 240 V AC; 0.8 A; 50Hz/60 HzPower Consumption(when fully mounted)KX-NCP500 51 W(240 V: 122 VA, 200 V: 113 VA, 130 V: 100 VA, 100 V: 92 VA)KX-NCP1000 65 W(240 V: 142 VA, 200 V: 134 VA, 130 V: 119 VA, 100 V: 113 VA)Maximum Power Failure Tolerance*1 300 msMemory Backup Duration 7 yearsDialing CO Line Dial Pulse (DP) 10 pps, 20 ppsTone (DTMF) DialingExtension Dial Pulse (DP) 10 pps, 20 ppsTone (DTMF) DialingMode Conversion DP-DTMF, DTMF-DPRing Frequency 20 Hz/25 Hz (selectable)Central Office Loop Limit 1600 W maximumOperatingEnvironmentTemperature 0 °C to 40 °C (32 °F to 104 °F)Humidity 10 % to 90 % (non-condensing)Conference Call CO Line From 10 ´ 3-party conference call to 4 ´ 8-party conference callMusic on Hold (MOH) 1 port (Level Control: -6 dB to +6 dB per 3 dB)MOH1: Selectable Internal/External Music Source portPaging Internal Level Control: -6 dB to +3 dB per 3 dBExternal 1 port (Volume Control: -15 dB to +6 dB per 3 dB)Serial Interface Port RS-232C 1 (maximum 115.2 kbps)RJ45 Port MNT Port 1 (for PC connection)LAN Port 1 (for LAN connection)Document Version 2011-10 Installation Manual 251.3.1 General Description