PushELBTest ButtonELBReset Lever3 TEST OPERATION2. • Turn “On” the Main Water Valve.• Turn clockwise the Water Volume Knob.• Check if water leaks from the Pipe Line.3. • Press the Push On-Off Lever once, the ELB lamp lights and water start flowing out of the Shower Head.• Turn the Power Control Knob clockwise and hot water flows out. (Adjust to suitable water temperature.)4. • Refer detail for HOW TO USE and WATER FLOW RATE ADJUSTMENT on page 21 and 22.1. • Before switch “ON” electricity supply check the wiring.• Switch “ON” the Miniature Circuit Breaker (MCB) and ON/OFF DP (double pole) Switch.• Set the ELB of the Unit to “On”. (Push up the ELB Reset Lever if it is down)• Push the ELB Test Button.• It is normal if the ELB turns “Off” (the ELB Reset Lever falls) and push the ELB Reset Lever up.Refer figure as shown.• Inspection on the built-in ELB (once a month) to avoid a hazard to users such as damage toproperty, serious injury or death.If the ELB Reset Lever cannot be reset even if you push it up or if it soon slides downduring operation, please do not use the Unit and contact the authorized dealerimmediately to avoid a hazard to users such as damage to property, serious injury ordeath. Never fix the ELB Reset Lever forcibly with tape, etc.WARNING3. TEST OPERATION- 30 -