58• Patrol Sensor Controlo First 2 minutes from Patrol function activates is stabilization time, during stabilization time, no air dirtinesslevel is monitored. The Air Dirtiness level is set to Clean, Patrol LED turns blue color.o After that, Patrol sensor starts to record the resistance value at fixed interval. Higher resistance valueindicates cleaner air.o The air dirtiness level is monitored by comparing the current resistance value with maximum resistance valuefrom time to time to get the Air Dirtiness Value.o There are 3 air dirtiness level, based on the Air Dirtiness Value: Air Dirtiness level 0: Clean – Patrol LED = blue color Air Dirtiness level 1: Moderate – Patrol LED = orange color Air Dirtiness level 2: Contaminated – Patrol LED = red colorAir Dirtiness Level 0Air Quality WorsenG1Air Dirtiness Level 1G3G2G4Air Dirtiness Level 2Air Quality Improve• Dirtiness level sensitivity adjustmentIt is possible to change the Patrol sensor sensitivity, where the Threshold value (G1 ~ G4) will be shiftedaccordingly:1 Press and release “SET” button.2 Press Timer ▲ / Timer ▼ button to select sensitivity.(Air 1 “Low Sensitivity” ↔ Air 2 “Standard” (Default) ↔ Air 3 “High Sensitivity”)3 Confirm setting by pressing “Timer Set” button. LCD returned to original display after 2 seconds.4 LCD returned to original display if remote control does not operate for 30 seconds• e-ion Controlo e-ion operation starts condition When dirtiness at level 2 (Patrol LED turns red). 2 minutes after stabilization time (Patrol LED turns red). 4 hours at level 0 (Patrol LED turns red).o e-ion operation time If dirtiness level improves from level 2 to level 1 (Patrol LED from red to orange), the unit carries out levelchange after 60 seconds. When dirtiness level returns to level 0 (Patrol LED turns blue) continuously for 11 minutes or more, e-ionoperation stops.• Dirtiness Level and fan speedo When e-ion operation starts, the fan speed increases based on dirtiness level:rpm shiftDirtiness level Patrol individualoperationCombine operationDirtiness level 0 No change No changeAuto ManualDirtiness level 1 + 20 +1 fan tap (max - Hi)e-ion ONDirtiness level 2 + 40No changeMe -Me +2 fan tap (max - Hi)o Indoor Fan Control During any operation mode combines with Patrol operation, fan speed follows respective operation mode. During Patrol individual operation if e-ion starts, only Auto Fan Speed and no Powerful operation isallowed. Even if “Fan Speed” button is pressed, no signal is sent to air conditioner, and no change onLCD display. During Patrol individual operation if e-ion stops, Indoor Fan stop operation.Air Dirtiness ValueDirty Moderate Clean