22Earth cable.A/B RS485 communication port. They are used tocontroldevicessuchasdecoder.120Ωshouldbeparallel connected between A, B lines if there aretoo many PTZ decoders.T+,T-,R+,R- They are four-wire full-duplex RS485 portT+ T-: output wireR+ R-: input wire3.7.2 Alarm Input PortPlease refer to the following sheet for more information. Grounding alarm inputs. Normal open or Normal close type) Please parallel connect COM end and GND end of the alarm detector (Provideexternal power to the alarm detector). Please parallel connect the Ground of the DVR and the ground of the alarm detector. Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM) Use the same ground with that of DVR if you use external power to the alarm device.Figure 3-23.7.3 Alarm Output Port Provide external power to external alarm device. To avoid overloading, please read the following relay parameters sheet carefully. RS485 A/B cable is for the A/B cable of the PTZ decoder. T+, T-, R+, R- are four-wire double duplex RS485 port.T+ T-: output wireR+ R-: input wireRelay SpecificationModel: JRC-27FMaterial of thetouch SilverRati Rated switch capacity 30VDC 2A, 125VAC 1A