40 (E)CONTENTSSetup menusThe underlined items indicates the initial setting.USER menu No./Item Description200PARA RUNThis selects whether two or more VTRs are tobe operated in synchronization.0000 DIS : No operation in synchronization0001 ENA : Operation in synchronizationWhen operating two or more VTRs insynchronization, set all the VTRs to ENA.202ID SELThis sets the ID information to be returned tothe controller.0000 OTHER0001 DVCPRO0002 ORIGOID information of any VTR except for theDVCPRO’s is set in OTHER.OThe ORIG setting should only be used when aPanasonic controller (AG-A850 etc. soldseparately) is connected.20325P SELThis selects whether the PARALLEL (25P)connector functions when the CONTROLswitch has been set to REMOTE.0000 OFF : Connector does not function.0001 ON : Connector functions.205BAUD RATEThese settings are for selecting the RS-232Ccommunication speed (baud rate).0000 3000001 6000002 12000003 24000004 48000005 9600204RS232C SELThis selects whether the RS-232C connectorfunctions when the CONTROL switch hasbeen set to REMOTE.0000 OFF : Connector does not function.0001 ON : Connector functions.206DATALENGTHThese settings are for selecting the RS-232Cdata length. (Unit: bit)0000 70001 8207STOP BITThese settings are for selecting the RS-232Cstop bit length. (Unit: bit)0000 10001 22019P SELThis selects whether the REMOTE (9P)connector functions when the CONTROLswitch has been set to REMOTE.0000 OFF : Connector does not function.0001 ON : Connector functions.208PARITYThese settings are for selecting the none, oddor even for the RS-232C parity bit.0000 NON :Parity bit is not used.0001 ODD:An odd number of bits is used for the paritysystem.0002 EVEN :An even number of bits is used for the paritysystem.No./Item Description209RETURN ACKThese settings are for selecting whether theACK code is to be returned when a commandis received from RS-232C.0000 OFF : ACK code is not returned.0001 ON : ACK code is returned.21025P STBYCMDFor selecting the method used to detect theSTANDBY COMMAND signal input at thePARALLEL (25P) connector.0000 OFF/ON :Each time active signals are detected, theSTANDBY ON or STANDBY OFF mode isselected alternately.0001 ON :When active signals are detected in theSTANDBY OFF mode, the unit is transferred tothe STANDBY ON mode.Nothing happens if they are detected during anoperation in the STANDBY ON mode.212MASTERPORTSD955B For selecting the remote control connector tocontrol the slave when the unit is used as themaster during deck-to-deck operations.0000 IN/OUT : The IN/OUT connector is used.0001 OUT : The OUT connector is used.This menu item takes effect only when theCONTROL switch has been set to the LOCALposition.211LOCAL 25PThis selects whether the PARALLEL (25P)connector is to function when the CONTROLswitch is at the LOCAL position.0000 OFF : Connector does not function.0001 ON : Connector functions.