Panasonic ACXF60-03410 Installation Manual
Also see for ACXF60-03410: Installation guide
1. Install the remote controller mounting plate to the wall with the two accessory screws 4.2. Fasten the screws properly until screw head is lower than the rib and reach the base of remote controllermounting plate to ensure they do not damage the PCB inside the remote controller 1.3. The feeding-out direction for the remote controller cable can be either via top, left or right side.4. Use nipper to cut a notch at the upper case. (Select the intended feeding-out position)5. Route the remote controller cable 2 inside the mounting plate in accordance with the intended feeding-outdirection. (Refer to the illustration at below)6. Insert firmly the connector of remote controller cable 2 to connector (CON1) in the upper case circuit board.(Refer to the illustration at below)7. Secure the remote controller upper case to the mounting plate with the tabs provided.1. Open the indoor control box cover by removing two pieces of screws.2. Remove the plugs at the side of the control box and fix the conduit connectors to knockout holes with lock nuts.Knockout holesConnectorsLock NutsControl Box PlugsScrewsControl Box cover3. Guide the remote controller cable 2 into the unit through the upper knockout hole and secure the cable to theholder.4. Firmly connect the connector of remote controller cable 2 to indoor unit PCB connector.5. Guide the remote controller cable 2 earth wire into the control box through the upper knockout hole.6. Fix the earth wire with a screw to the grounding location provided in the control box.Earth wire (remote controller cable)Indoor/outdoor connection cable inletFix remote controller cable connectorRemote controller cable 2Fix remote controller cableto the holder7. Install back the control box cover. Be careful not to clamp the cable in between control box and control box cover.Control box coverIndoor unitControl boxRemote controller 1WallUpper caseUpper tabMounting plateScrews 4Lower tabRemote controller cable 2Connector (CON1)3. CONNECTING THE REMOTE CONTROLLER CABLE TO INDOOR UNITUpper caseGapsACXF60-034101. R e m o v e t h e r e m o t e c o n t r o l l e r 1 m o u n t i n g p l a t e .(Insert a fl at-tipped screw driver or similar tool 3/32" to 1/8" (2 to3 mm) into one of the gaps at the bottom of the case, and twistto open. Refer to the illustration at right.)Be careful not to damage the mounting plate.2. Do not remove the protective tape which is affixed to theupper case circuit board when removing the remote controllermounting plate.3. Secure the mounting plate to an outlet box or wall. Refer to (A)or (B) instructions below depending on your choice of cableinstallation.4. Be sure to use only the screws provided.5. Do not over tighten the screws, as it may result in damage tothe mounting plate.2. INSTALLING THE REMOTE CONTROLLER UNIT TO THE WALLScrewdriverScrew 3orScrew 41. Embed an outlet box into the wall. Outlet box may be purchased separately. Medium-sized square outlet box(obtain locally) Part No. DS3744 (Panasonic Corporation) or equivalent.2. Secure the remote controller mounting plate to the outlet box with the two accessory screws 3 .Make sure that the mounting plate is flat against the wall at this time, with no bending.3. Pass the remote controller cable 2 into the box.4. Route the remote controller cable 2 inside the mounting plate through rear feeding-out direction.5. Insert fi rmly the connector of remote controller cable 2 to connector (CON1) in the upper case circuit board.[Refer to the illustration at below.]6. Secure the remote controller upper case to the mounting plate with the tabs provided.WallUpper caseMounting plateUpper tabConnector (CON1)Screw 3Lower tabOutlet boxB. IF REMOTE CONTROLLER CABLE IS EXPOSEDRibScrews 4WallRemote controllermounting plateSAFETY PRECAUTIONS• Read the following “SAFETY PRECAUTIONS” carefully before installation.• Electrical work must be installed by a licensed electrician.• The caution items stated here must be followed because these important contents are related to safety. The meaningof each indication used is as below.Incorrect installation due to the non-observance of the instructions will cause harm or damage, and the seriousness isclassified by the following indications.• Perform a functional test to confirm that no abnormality occurs after the installation. Then, explain the operation,care and maintenance to user as stated in instructions. Please remind the customer to keep the operatinginstructions and installation instruction for future reference.A. IF REMOTE CONTROLLER CABLE IS EMBEDDED• Allow suffi cient space around the remote controller 1 as shown in the illustration above.• Install in a place which is away from direct sunlight and high humidity.• Install on a flat surface to avoid warping of the remote controller. If installed to a wall with an uneven surface,damage to the LCD case or operation problems may result.• Install in a place where the LCD can be easily seen for operation. (Standard height from the floor is 3.9ft to 4.9ft(1.2 to 1.5 meters.))• Avoid installing the remote controller cable near refrigerant pipes or drain pipes, otherwise it will cause electricalshock or fire.1. SELECTING THE INSTALLATION LOCATIONRemotecontrollercable 2Rear feeding-outpositionMounting plateConnector(CON1)Upper caseTabsUpper caseMounting plateRemotecontrollermountingplate1 3/16"( 30mm)or more1 3/16"( 30mm)or more1 3/16"( 30mm)or more4 23/32"(120mm)or moreUpper caseMounting plateRemote controller 1ATTACHED ACCESSORIESMounting plateRemotecontrollercable 2WARNING This indication shows the possibility of causing death or serious injury.CAUTION This indication shows the possibility of causing injury or damage to properties only.The items to be followed are classified by the symbols:Symbol with white background denotes item that is PROHIBITED from doing.Symbol with dark background denotes item that must be carried out.Wired Remote Controller Installation ManualWARNINGDo not modify the length of the remote controller cable. Otherwise, it will cause fire or electrical shock.Be sure to turn off the main power before installing and connecting the remote controller. Otherwise, it willcause electrical shock.Engage an authorized dealer or specialist for installation. If installation done by the user is defective, it willcause electrical shock or fire.Install strictly according to these installation instructions. If installation is defective, it will cause electrical shockor fire.Use specified accessories and parts for installation. Otherwise, it will cause the set to fall, fire or electricalshock.For electrical work, follow the local national wiring standards and regulations, and these installationinstructions. Otherwise, it will cause electrical shock or fire.Wire routing must be properly arranged so that control board cover is affixed properly. If control board cover isnot affixed perfectly, it will cause fire or electrical shock.If passing the remote controller cable through a wall, be sure to install a water trap above the cable.Otherwise, it will cause electrical shock.CAUTIONDo not touch the sharp aluminium fin of air conditioner unit during wired remote controller installation, sharpparts may cause injury.Install on a flat surface to avoid warping of remote controller, or else damage to the LCD case or operationproblems may result.Avoid installing the remote controller cable near refrigerant pipes or drain pipes, otherwise it will causeelectrical shock or fire.Install the remote controller cable at least 1 31/32"(5cm) away from electric wires of other appliances to avoidmisoperation (electromagnetic noise).Be sure to use only the accessory screws to avoid damage of remote controller PCB.No. Name Qty Diagram Remark1 Remote controller 12 Remote controller cable 1 Length 32.8ft (10m)3Screw(M4 machine pitched - 1 3/16"30mm))3 Installing the remote controller to an outlet box(embedded cable)4 Screw(M4 self tapping - 9/16"(14mm)) 3 Installing the remote controller to the wall(exposed cable)CAUTIONWhen the wall is hollow, please be sure to usethe sleeve for remote controller cable to preventdangers caused by mice biting the cable.CAUTIONBe sure to turn off the main power before installing and connecting the remote controller.Otherwise, it will cause electrical shock.Upper caseMounting plateRightfeeding-outMounting plateConnector(CON1)Upper caseNotchesRemotecontrollercable 2TabsLeft feeding-outpositionTop feeding-outposition Remote controller 1ACXF60-03410ENGLISH1 2 |
Related manuals for Panasonic ACXF60-03410
Panasonic ACXF60-03410 Installation Manual
Panasonic CZ-RE2C2 Installation Manual
Panasonic CZ-RD516C-1 Installation Manual
Panasonic CZ-RD516C-1 Installation Manual
Panasonic CZ-ANC2 Installation Instructions Manual
Panasonic CZ-ANC3 Installation Instructions Manual
Panasonic CZ-RWS3 Installation Instructions Manual
Panasonic CZ-64ESMC3 Installation Instructions Manual
Panasonic CZ-64ESMC3 Installation Instructions Manual
Panasonic CZ-256ESMC2U Installation Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved