Nuaire Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NAT: 029 2088 5911 F: 029 2088 7033 E: info@nuaire.co.uk W: www.nuaire.co.uk1"Warning: For EMC compliance the 12V cable should not befitted within 50mm of 230V or other cables or on thesame tray/trunking if made of metal. The earth connectionin the transformer enclosure should not be used.No earth connection should be made to the 12V fan unit"11. 05. 17. Leaflet Number 671182Genie 12V and 230VUniversal SurfaceMounted FansInstallation and MaintenanceFigure 1. Surface mounted, wall.Figure 2.Figure 3.CoverscrewsFixings byothersFinishingPlate 3 set screw(supplied)MountingPlateFigure 4. Semi-recessed mounted, ceiling. First cut an aperture forthe fan in the ceiling, cut and fit (A) timber supports (not supplied)and fit fan as shown.Figure 5. Semi-recessed mounted, wall.NB. Base drill pattern superimposedon page 2.NB. The discharge spigot is 98mm od.The hole in the structure should thereforebe of a dimension to accomodate anyducting or cavity lining used.Press to releasecoversAA AACeilingMountingPlateCeilingThe EMC Directive2014/30/EUThe Low VoltageDirective2014/35/EUGenie FansThe Genie range of fans has been specifically designed toventilate small rooms such as toilets, bathrooms, cloakroomsetc and can be surface and recessed mounting.* An optional window mounting kit is available for this unit,code ref WINKIT.Air entering the unit passes through a washable filter fitted to thefront cover. Anti-backdraught shutters, retained in the closedposition when fan is not running, are fitted to the base plate.Motor has sealed, self lubricating bearings and “heatseeker”thermal overload protection. The fan/ motor assembly is retainedby spring clips to simplify maintenance.Interchangeable plug in electronic control modules can incorporate:■ Run - on timer■ Humidistat■ Continuous low duty with boost.As a safety feature the fan/motor assembly is automaticallydisconnected when the electronic control module is removed.Warning: when installing Genie units for remote switching it isimportant that the pull cord (if fitted) is removed.It is recommended that the unit is switched off (by the pullcord)before cutting. Cut the pullcord inside the unit a little waybeyond the control module.Fan InstallationTo be carried out by qualified personnel only.Surface MountingNote. It is assumed that a solid mounting position has beenselected and passages for ductwork from the outlet spigot,as well as electrical connection prepared. In addition thatcompatible ductwork has been installed.1. Remove cover/grille assembly by removing cover screws.Depress the top/bottom retaining tabs. (Fig. 2).2. Remove the plug-in electronic controlmodule. (Fig. 3).3. Remove the fan/motor assembly bypulling aside the two spring clips.4. Place the unit in the mounting position,connect the ductwork and feed the cablethrough the cable entry. Connect thewiring to the terminal block (it may beeasier to temporarily remove the block tofacilitate wiring).5. Drill and plug the mounting surface if necessary and secure theunit in position, using three No. 6 wood screws.6. Fit the fan assembly to the case, securing itwith the two spring clips. Install the electroniccontrol module ensuring that it is fully engagedin the internal socket. If the pull-cord option isrequired it should be fed through theaperture on the impeller housing beforesliding the control moduleinto place. (see fig. 6).If the pullcord option isnot required it must beremoved.Replace the front cover.7. Fit the filter which is a push fit between the front cover and thebody of the unit (see fig. 2).8. Test run the unit noting that if a timer/humidistat option isfitted, the unit may run-on for the duration of the control sequence.Semi-Recessed MountingImportant note: Remove the shutters from the spigot if you aremounting the Genie in the ceiling.