NAPCO GEM-RP8LCD Installation Instructions Manual
Also see for GEM-RP8LCD: Operating guideOperating guide
Page 2KEYPAD CONFIGURATION MODEFeedback Beep (Default = ON)Upon entering the Keypad Configuration Mode (press C any timeto exit), ìFeedback Beep Presently ONî displays, indicating that thetactile beep, which sounds when any button is pressed, is on. To turnoff the tactile feedback beep, press U. The tactile feedback beep willimmediately turn off, and the system will advance to the next selection(Keypad Sounder). If feedback beep is off and you wish to turn it onagain, press B (to scroll back). Display will read ìFeedback BeepPresently OFFî. Press U to turn on.Keypad Sounder (Default = ON)To turn off the keypad sounder, press U. All keypad sounds will be off,except for the Feedback Beep. Do not program in U.L. installations.E/E Countdown (Display) (Default = ON)Exit delay allows time for the user to leave the premises after arming;entry delay provides the user time to enter and disarm. To turn off (orturn on) the display of the exit/entry delay countdown, press U.Note: Requires times to be entered. See Exit/Entry Time Display onnext page. Note: Factory program defaults to 30 and 45 seconds forEntry and Exit delays, respectively.Display Zn Fault (Default = ON)To turn off the scrolling display of zone faults, press U. If faultedzones exist and this setting is OFF, window will only display ìZoneFaultedî and not scroll zones.Keypad PGM Opt (Default = OFF)A common use of this feature is to activate a door strike for thepurposes of remotely unlocking a door. The PGM is a switchednegative output that is activated when this option is selected and bypressing U. If this option is OFF, the Activate Access function will notdisplay in the Function Menu. Connect the device controlled by thePGM between +PWR and the PGM terminal (maximum load of 10mA). The PGM Output will remain ON for approximately 7 seconds.Dialer Test Opt (Default = OFF)Testing the dialer is initiated through the Function Menu. Turning ONthe Dialer Test Item enables the Activate Dialer Test entry to be listedin the Function Menu. If turned OFF, the Activate Dialer Test entry isremoved from the Function Menu. The Dialer Test Option is not sup-ported with the GEM-P800 and therefore must be turned off here ifused with this panel.Easy Exit Option (Default = OFF)This option allows a user to exit the premises while the system is armed. IfOFF, the Easy Exit function will not display in the Function Menu. TurnOFF if not enabled in Panel. This feature should not be used in U.L. instal-lations.Ready Message Option (Default = OFF)An alternate message can be used in place of the default ìSYSTEMREADYî message when keypad is in a normal state. The alternatemessage is ìREADY TO ARMî but can be changed to any other textmessage by using the PC Quickloader software.Keypad Panics F=4 A=2 P=1 (Default = 7)Each Panic Zone is always a 24-Hour Zone, and each keypad can beindividually programmed for keypad panics. Enter the sum of the dis-played numbers to activate the selected Panic Zone(s) as follows:If ìKeypad Panicî (P) is programmed for a keypad, police panic isactivated by pressing 9 and G. If ìKeypad Aux.î (A) isprogrammed, pressing 8 G will trip an auxiliary emergencyalarm. If ìKeypad Fireî (F) is programmed, pressing 7 and Gwill activate fire panic. These features must also be enabled in panel pro-gramming via Dealer Mode. Press U to save your selection. U.L. Installa-tions: If Keypad Fire [20-1] is enabled, the keypad must be mounted within(3) three feet from the Control Panel with no intervening walls or barriers.Keypad Address (Default = 0)Each keypad must be assigned a unique keypad address (that is, notwo keypads may be numbered alike) in order for the PCD WindowsDownloader software to correctly configure the keypads. Keypadsmust be numbered consecutively, and missing numbers are notpermitted. To assign the keypad number, enter the assigned keypadnumber 1ñ4, then press U to save.EZM Address (Default = 0)The GEM-RP8LCD keypad includes an internal EZM (Expansion ZoneModule) that may be enabled to provide two additional hard wiredzones, assigned to zones 7 & 8. The system will support up to 2EZMs, EZM1 and EZM2. If the EZM is not used, the EZM addressmust be left at the default of ì0î. To enable the EZM in the keypad,enter an EZM address of ì1î or ì2î, and press U to save.• If 2 Keypad EZM zones are required from one keypad, enable EZM1 (1).• If only 1 Keypad EZM zone is required, enable keypad EZM1 (1).• If 1 Keypad EZM zone is required from one keypad and 1 zone fromanother, enable EZM1 (1) in one keypad and EZM2 (2) in the other.EZM Zones Enable (Default = 3)** EZM Address must be 1 or 2 for Zones to be enabled.After the Keypad EZM has been enabled, the Zone(s) to be used onthe Keypad EZM must also be enabled as follows:• To enable EZM zone 1, enter 1 on the display and press U.• To enable EZM zone 2, enter 2 on the display and press U.• To enable both EZM zones 1 and 2, enter 3 and press U.NOTE: If zones are enabled, then 2.2K EOL resistor (provided)must be used (in parallel with N/O, in series with N/C devices).Assigning EZM Zones in Dealer Program ModeIn addition to configuring the keypad, the panel must be programmedfor the use of keypad EZM zones. These zones must be mapped tozones 7 & 8 in the same fashion as RF transmitters - by entering aspecial RF ID and point # in blocks 77 & 78, as follows:Keypad configured as EZM 1:To enable Zone 1 on Keypad EZM 1:1. Enable EZM Address 1 as described above.2. Enable EZM zone 1 as described above in ìEZM Zones Enableî.3. Go to block 77 and enter RF ID# 111111:5-1 (point 1) to map tozone 7 (or block 78 to map to zone 8).4. Wire zone device to the keypad Orange and Gray wires.To enable Zone 2 on Keypad EZM 1:1. Enable EZM Address 1 as described above.2. Enable EZM zone 2 as described above in ìEZM Zones Enableî.3. Go to block 77 and enter RF ID# 111111:5-2 (point 2) to map tozone 7 (or block 78 to map to zone 8).4. Wire zone device to the keypad Blue and Gray wires.Keypad configured as EZM 2:To enable Zone 1 on Keypad EZM 2:1. Enable EZM Address 2 as described above.2. Enable EZM zone 1 as described above in ìEZM Zones Enableî.3. Go to block 77 and enter RF ID# 222222:b-1 (point 1) to map tozone 7 (or block 78 to map to zone 8).4. Wire zone device to the keypad Orange and Gray wires.To enable Zone 2 on Keypad EZM 2:1. Enable EZM Address 2 as described above.2. Enable EZM zone 2 as described above in ìEZM Zones Enableî.3. Go to block 77 and enter RF ID# 222222:b-2 (point 2) to map tozone 7 (or block 78 to map to zone 8).1=Panic 2=Aux 3=Panic & Aux 4=Fire5=Panic & Fire 6=Aux & Fire 7=Panic, Aux & Fire 0=None |
Related manuals for NAPCO GEM-RP8LCD
NAPCO GEM-RP3DGTL Installation Instructions Manual
NAPCO GEM-K4RF Installation Instructions Manual
NAPCO GEM-P1632 Installation Instructions Manual
NAPCO RP2000LCD Installation Instructions Manual
NAPCO RP1054e Installation Instructions Manual
NAPCO RPXP6GT Installation Instructions Manual
NAPCO GEM-TOUCH Gemini Series Installation Instructions Manual
NAPCO RP1054e Installation Manual
NAPCO LIBRA DXK4RF-319 Installation Instructions Manual
NAPCO Gem-RP8LCD Operating Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved