Mitsubishi Electric PAR-SL94B-E Installation Manual
Also see for PAR-SL94B-E: User instructions
Slide forward6 Connecting the receiver board connector to the control circuit board5 Removing the beam and the electrical box cover4 Laying out the lead wire3 Installing to the indoor unitRG79V995H03Package Air-ConditionerWireless remote controller kit PAR-SL94B-EInstallation Manual● After using this manual, be sure to pass it to the customer together with the instruction manual provided with the indoor unit.Ask the customer to keep this installation manual and the instruction manual in a handy place, and to show them to theengineer when the air-conditioner is moved or repaired. Also ask the customer to pass them to any new user.Safety Precautions● Read these “Safety Precautions” thoroughly and install securely.● Precautions are classified using the following symbols depending on the extent and type of danger by erroneous handling.WARNINGCAUTIONErroneous handling can cause death or serious injury.Erroneous handling can cause personal injury or damage.This manual describes the installation for wireless remote controller kit of the Mitsubishi ceiling suspended series packageair-conditioner. Read this manual carefully.WARNINGAsk a dealer or specialist to install the unit.Securely install the unit in a place that can with stand theweight.• Otherwise, the unit could fall, which could cause injury.Never modify the unit or repair it by yourself.• Modification or incorrect repair could cause electric shock,fire, etc. Consult the dealer from whom you purchased the unit.Do not move the unit by yourself.• Incomplete installation could cause electric shock, fire,etc. Ask the dealer or a specialist for installation.Securely install the unit, referring to this installation manual.• Incomplete installation could cause electric shock, fire,etc.All accessories must be installed by an authorized technician.• The user must not try to install accessories. Improperlyinstalled accessories can cause water leakage, electricshock or fire. Shortage in electrical circuit capacity orincomplete construction could cause fire, etc.Securely connect the specified remote control cord, andfix it so that the terminal connector is free from any externalforce via the cord.• Incomplete connection or fixing could cause heat, fire, etc.CAUTIONDo not install the unit in a place where flammable gas could leak.• If gas leaks or accumulates around the unit, it could causeignition, explosion, etc.Do not use the unit in an abnormal environment.• Usage in a place where there is much oil (including machineoil), steam, sulfide gas, etc. could greatly degrade its perfor-mance or damage components.Do not install the unit in a bathroom, kitchen, etc. where agreat amount of steam is generated.• Avoid installing in a wall where condensation occurs. Insta-lling in such a place could cause a fault, electric shock, etc.Do not install the unit in a place where acid solution, alkalinesolution, special spray, etc. are frequently used.• Installing in such a place could cause fault, electric shock, etc.Take sufficient countermeasures against noise when the unit is installed in hospital, communication office, etc.• This unit could malfunction when affected by inverter equipment, private electric generator, high-frequency medical instru-ments, radio communication devices, etc. Also, this unit could adversely affect medical instruments, communication devices,etc., thus interfering with human medical treatment, or causing disturbance in broadcast pictures or noise.When doing wiring, make sure that wires are not subjectto tension.• Tension on wires could disconnect them, or cause heat, fire, etc.Do not rinse this unit with water.• Doing so could cause fault, electric shock, etc.Do not install the unit in a place where the ambient temperatureis over 40°C or below 0°C, or exposed to direct sunlight.• Installing in such a place could cause deformation, fault, etc.Do not touch circuit boards with hands or tools, or allowdust to adhere to them.• Failure to do so could cause fault, fire, etc.Do not operate buttons with wet hands.• Failure to do so could cause fault, electric shock, etc.Do not push buttons with sharp objects.• Failure to do so could cause fault, electric shock, etc.Making Sure of ComponentsMake sure that the following components, along with this manual, are packed in the box.ComponentWireless remote controller receiverWireless remote controllerRemote control holder“AAA” LR03 alkaline batteries4.1×16 wood screwsCord retaining clipsConnection cord fixing seal (12×30 size)1112221How to Install W Be sure to turn the power off before installing.1 Removing the intake grille and the right side panel• Slide the catch holding the intake grille backwards to open the grille. Remove the screw holding the side panel.Remove the side panel support hanger, and then slide the side panel forward to remove it.Side panelCatch retaining the intake grilleRemove the screw holding the side panel2 Removing the existing brand label case• Pass the receiver board connector through the right side of the square hole to which the brand label casewas attached and then pull the connector and cord through the slit in the right side of the bottom panel.• Fit the receiver into the square hole where the brand label case was attached.Retaining clipSlit• Pass the lead wire for receiver through the retaining clips.• Fix the lead wire for receiver with the clips on the ceiling sideof the unit.Retaining clipClips on the ceiling side• Remove the beam.• Loosen the two screws at the bottom of the electrical box cover,and then slide the cover to the left to remove it.• Pull down the electrical box.{ Electrical box fixing screwElectrical box cover fixing screwElectrical box coverBeam• Pass the cord through the bush at the top right of the electrical box.• Connect the connector to CN90 on the right of the control board.• If the cord is loose, bundle it using the clamps under the above bush. CN90BushClampsClampsPair Number Setting8 Remote control holder• To install the wireless remote controller on a wall, first attach the remote control holder to a wall.132Fitting remote control into holder1 Fix the remote control holder to the wall usingthe 2 wood screws provided.2 Insert the remote control into the holder.3 Push the remote control against the wall.Removing remote control● Pull the top of remote control forward.NOTE : The remote signal will reach the receiver over a distance of approx. 7m in a straight line and approx. 45°left or right. If the infrared receiver is affected by fluorescent light (especially, inverter type), it may not beable to receive the signal. Take this into consideration when installing fluorescent lights or replacing them.• This is the setting to specify the unit to operate with the wireless remote controller.• Make setting for J41, J42 (Jumper wire) of indoor controller board and the pair number of wireless remote controller.• The pair number setting is available with the 4 patterns as shown in the following table. Make setting for the pair number(J41, J42) of indoor controller board and the pair number of wireless remote controller which is usedas shown in the following table. *The initial setting is Pair No. “0”.1 Press the SET button with something sharp at the end.Start this operation from the status of remote controller display turned off.MODEL SELECT blinks and Model No. is lighted.2 Press the button twice continuously. Pair No. “0” blinks.3 Press the temp button to set the pair number you want to set.4 Press the SET button with something sharp at the end.Set pair number is lighted for 3 seconds then turned off.A Pair No. of wireless remote controller Indoor PC boardInitial settingCut J41Cut J42Cut J41, J420123 ~ 9CN90minModel SelectThis remote controller needs model number setting before use.Set the model number in the following order.Without setting the air conditioner will not work property.(The factory setting of model number is “001”.)1 Insert batteries.2 Press the SET button with something sharp at the end.MODE SELECT blinks and Model No. is lighted.3 Press the temp button to set the Model Number.4 Press the SET button with something sharp at the end.MODE SELECT and Model No. are lighted for 3 seconds, then turned off.Jumper wire (J41, J42)SlideSlide• Incomplete installation could cause electric shock, fire, etc.Also on theopposite sideON/OFF TEMPFANVANEMODECHECK LOUVERTEST RUNAUTO STOPAUTO STARThminRESETSET CLOCKMODEL SELECT A321 4Q’ty7 Reinstalling the removed components• Reinstall the removed components in reverse order. (The brand label case is not needed.)* The positions of the connectors may be different according to the model.Please refer to the wiring diagram to confirm the positions of the connectors.* The positions of the connectors may bedifferent according to the model.Please refer to the wiring diagram toconfirm the positions of the connectors.Panel CasePanelON/OFF TEMPFANVANEMODECHECK LOUVERTEST RUNAUTO STOPAUTO STARThminRESETSET CLOCKMODEL SELECTModelNumber32 45Indoor Unit ModelPCA-RP. KAPC-KAKPCFY-P. KM(H/P)/(C/O)OutdoorHeat pumpOutdoorCooling onlyCooling onlyOutdoor: Separateheating and coolingOutdoor: Simultaneousheating(PURY) and coolingIndoor: Cooling onlyModel No.001033035225001033• Remove the brand label case (name plate withMITSUBISHI ELECTRIC) from the bottom rightof the unit. If it is difficult to remove the case,use a flat-blade screwdriver, etc., taking care not todamage the panel. Slide forwardside panelsupport hangerhole for side panelsupport hanger |
Related manuals for Mitsubishi Electric PAR-SL94B-E
Mitsubishi Electric PAR-SL100A-E Installation Manual
Mitsubishi Electric PAR-SW96U-E Installation Manual
Mitsubishi Electric PAR-30MAA Installation Manual
Mitsubishi Electric PAR-21MAA Installation Manual
Mitsubishi Electric PAR-20MAA Installation Manual
Mitsubishi Electric PAR-21MAA Installation Manual
Mitsubishi Electric PAR-30MAA Installation Manual
Mitsubishi Electric PAR-21MAA Installation Manual
Mitsubishi Electric PAR-32MAA Installation Manual
Mitsubishi Electric PAR-W21MAA Installation Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved