Mitsubishi Electric MELSEC-F FX3U-4AD-ADP User Manual
Also see for FX3U SERIES: Hardware manualUser manualProgramming manualBeginners manualStructured programming manual
SideASideBJAPANESEENGLISHJY997D13901NSideBSafety Precautions (Read these precautions before use.)This manual classifies the safety precautions into two categories:and .Depending on the circumstances, procedures indicated by mayalso cause severe injury.It is important to follow all precautions for personal safety.Associated ManualsHow to obtain manualsFor product manuals or documents, consult with the Mitsubishi Electric dealerfrom who you purchased your product.Indicates that incorrect handling may cause hazardousconditions, resulting in death or severe injury.Indicates that incorrect handling may cause hazardousconditions, resulting in medium or slight personal injuryor physical damage.Manual name Manual No. DescriptionFX 3S /FX 3G /FX 3GC /FX 3U /FX 3UC SeriesUser's Manual- Analog Control EditionJY997D16701MODEL CODE:09R619Describes specifications foranalog control andprogramming method forFX3S /FX3G /FX 3GC/FX 3U/FX3UC Series PLC.FX 3S /FX 3G /FX 3GC /FX 3U /FX 3UC SeriesProgramming Manual- Basic & AppliedInstruction EditionJY997D16601MODEL CODE:09R517Describes PLC programmingfor basic/applied instructionsand devices.FX 3S SeriesUser’s Manual- Hardware EditionJY997D48601MODEL CODE:09R535Explains FX 3S Series PLCspecifications for I/O, wiring,installation, and maintenance.FX 3G SeriesUser’s Manual- Hardware EditionJY997D31301MODEL CODE:09R521Explains FX 3G Series PLCspecifications for I/O, wiring,installation, and maintenance.FX 3GC SeriesUser’s Manual- Hardware EditionJY997D45401MODEL CODE:09R533Explains FX 3GC Series PLCspecifications for I/O, wiring,installation, and maintenance.FX 3U SeriesUser’s Manual- Hardware EditionJY997D16501MODEL CODE:09R516Explains FX 3U Series PLCspecifications for I/O, wiring,installation, and maintenance.FX 3UC SeriesUser’s Manual- Hardware EditionJY997D28701MODEL CODE:09R519Explains FX 3UC Series PLCspecifications for I/O, wiring,installation, and maintenance.Applicable standardsFX 3U-4AD-ADP units made in June, 2005 or later comply with the EC Directive (EMCDirective) and UL standards (UL, cUL). Further information can be found in thefollowing manual.→ FX3S Series Hardware Manual (Manual No. JY997D48301)→ FX3G Series Hardware Manual (Manual No. JY997D46001)→ FX3GC Series Hardware Manual (Manual No. JY997D45201)→ FX3U Series Hardware Manual (Manual No. JY997D50301)→ FX3UC (D, DS, DSS) Series Hardware Manual (Manual No. JY997D50501)→ FX 3UC-32MT-LT-2 Hardware Manual (Manual No. JY997D31601)Regarding the standards that relate to the main unit, please refer to either the FXseries product catalog or consult with your nearest Mitsubishi product provider.AttentionThis product is designed for use in industrial applications.Caution for EC DirectiveThe analog special adapters have been found to be compliant to the Europeanstandards in the aforesaid manual and directive. However, for the very best per-formance from what are in fact delicate measuring and controlled output deviceMitsubishi Electric would like to make the following points;As analog devices are sensitive by nature, their use should be considered care-fully. For users of proprietary cables (integral with sensors or actuators), theseusers should follow those manufacturers installation requirements.Mitsubishi Electric recommend that shielded cables should be used. If NO otherEMC protection is provided, then users may experience temporary loss oraccuracy between ±10 % in very heavy industrial areas.However, Mitsubishi Electric suggest that if adequate EMC precautions are fol-lowed for the users complete control system, users should expect accuracy asspecified in this manual.• Sensitive analog cable should not be laid in the same trunking or cableconduit as high voltage cabling. Where possible users should run analogcables separately.• Good cable shielding should be used. When terminating the shield at Earth- ensure that no earth loops are accidentally created.• When reading analog values, EMC accuracy can be improved out byaveraging the readings. This can be achieved either through functions on theanalog special adapters or through a users program.1. OutlineThe FX 3U-4AD-ADP special adapter for analog input (hereinafter called 4AD-ADP) is aspecial adapter to add four analog input points.1.1 Incorporated ItemsVerify that the following product and items are included in the package:Product FX3U -4AD-ADP analog input special adapterAccessories User’s manual (This manual)1.2 External Dimensions, Part Names, and Terminal Layout2. InstallationFor installation/uninstallation details, refer to the respective PLC User's manualHardware Edition.[1] DIN rail mounting groove (DIN rail: DIN46277)[2] Name plate[3] Special adapter slide lock:Used to connect additional special adapters onto the left side of this specialadapter.[4] Special adapter connector cover:Remove this cover to connect additional special adapters to the left side.[5] Direct mounting hole:2 holes of φ4.5 (0.18") (mounting screw: M4 screw)Not used when connecting to FX3GC /FX 3UC Series PLC.[6] POWER LED (green):Lit while 24 V DC power is supplied properly to terminals '24+' and '24-'.[7] Terminal block (European type):Connect the analog voltage/current signal, and 24 V DC power supply.[8] Special adapter connector:Used to connect this special adapter to PLC main unit or special adapter.[9] DIN rail mounting hook[10] Special adapter fixing hook[11] Special adapter connector:Used to connect communication or analog special adapters to the left side of the4AD-ADP.INSTALLATIONPRECAUTIONS• Make sure to cut off all phases of the power supply externally before attemptinginstallation or wiring work.Failure to do so may cause electric shock or damage to the product.INSTALLATIONPRECAUTIONS• Use the product within the generic environment specifications described in PLCmain unit manual (Hardware Edition).Never use the product in areas with excessive dust, oily smoke, conductive dusts,corrosive gas (salt air, Cl 2 , H 2 S, SO 2 , or NO 2 ), flammable gas, vibration orimpacts, or expose it to high temperature, condensation, or rain and wind.If the product is used in such conditions, electric shock, fire, malfunctions,deterioration or damage may occur.• When drilling screw holes or wiring, make sure cutting or wire debris does notenter the ventilation slits.Failure to do so may cause fire, equipment failures or malfunctions.• Do not touch the conductive parts of the product directly.Doing so may cause device failures or malfunctions.• Connect special adapter securely to their designated connectors.Loose connections may cause malfunctions.7(0.28") 74(2.92") 15.5(0.62")90(3.55")98(3.86")(mounting hole pitch)106(4.18")17.6(0.7")15.1(0.6")[6][5] [10][7][8][9][3][2][4]Weight: Approx. 0.1 kg (0.22 lbs)Special adapterconnector coveris removed[11][1]V1+I1+COM1V3+I3+24+24-V2+I2+V4+I4+COM4COM3COM22.1 Connection to the PLCThis section describes the connection method to the PLC (FX3U Series PLC isused for the following example).For installation method to other PLCs, refer to the respective PLC User's manualHardware Edition.Procedure1) Turn off the power.Disconnect all the cables connected to the PLC main unit and special adapter,and demount the main unit and special adapter mounted on DIN rail ormounted directly using screws.2) Install an expansion board to the main unit.For the expansion board installation procedure, refer to the following manual:→ FX 3U Series User's Manual - Hardware Edition3) Remove the special adapter connector coveron the expansion board (fig.A).When connecting this product to anotherspecial adapter, please replace the'expansion board' in the above descriptionwith a 'special adapter' and perform theprocedure as indicated.4) Slide the special adapter slide lock(fig.B) of the main unit.When connecting this product to anotherspecial adapter, please replace the 'mainunit' in the above description with a 'specialadapter' and perform the procedure asindicated. (Please replace the followingprocedures similarly.)5) Connect thespecial adapter(fig.C) to themain unit asshown on theright.6) Slide back thespecial adapterslide lock (fig.B)of the main unitto fix the specialadapter (fig.C).Connection precautionsConnect all the high-speed I/O special adapters before connecting otherspecial adapters when they are used in combination.Do not connect a high-speed I/O special adapter on the left side of anyspecial adapters other than other high-speed I/O special adapters.RUNSTOPFXFX3U -48MR/ES-48MR/ESFX3U-48M3)4)BBA4)RUNSTOPFX3U-48MR/ES-48MR/ESFXFX3U-48MPOWERFX 3U-*** -***FX3U-48M6)CBB5)5)5)6)FX3U-4AD-ADPUSER'S MANUALThis manual describes the part names, dimensions, mounting, and specificationsof the product. Before use, read this manual and the manuals of all relevantproducts fully to acquire proficiency in handling and operating the product. Makesure to learn all the product information, safety information, and precautions.Store this manual in a safe place so that it can be taken out and read whenevernecessary. Always forward it to the end user.Registration:The company and product names described in this manual are registeredtrademarks or the trademarks of their respective companies.Effective May 2018Specifications are subject to change without notice.© 2005 Mitsubishi Electric CorporationManual Number JY997D13901Revision NDate May 2018 |
Related manuals for Mitsubishi Electric FX3U SERIES
Mitsubishi Electric MELSEC FX3U-4DA-ADP User Manual
Mitsubishi Electric MELSEC-F FX3U User Manual
Mitsubishi Electric FX3U-4AD-TC-ADP User Manual
Mitsubishi Electric FX3U-4AD-PNK-ADP User Manual
Mitsubishi Electric FX3U-4AD-PTW-ADP User Manual
Mitsubishi Electric FX3U-4DA-ADP User Manual
Mitsubishi Electric FX3U-3A-ADP User Manual
Mitsubishi Electric MELSEC-F FX-USB-AW User Manual
Mitsubishi Electric MELSEC-A User Manual
Mitsubishi Electric MELSEC-A User Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved