14240 Volt installationsPermanently ConnectedModels:Refer to the manufacturer’s nameplate located onthe kick plate to determine you spa’s ampererequirements.Electrical Requirements:240 Volts, 60Hz, Single Phase, 40, 50 or 60 amp. 4-wire service (line 1, line 2, neutral, and ground),Note: The heater can be activated only with thepump on low speed. Only the spa light can beoperating at the same time without disabling theheater. See your authorized dealer if select thisoption.Spas installed for 240 volt operation require a 4-wire, 40 or 50 amp. 240 volt sub-feed in non-metallicpipe to the spa equipment compartment (line 1, line 2,neutral, and ground).All connections must be done accordingly to theCSA International regulation (Canadian StandardAdministration).A green colored terminal (or wire connectormarked “G”, or “GR”, “Grounding”) is provided in thecontrol box. To reduce the risk of electrical shock,connect this terminal or connector to the groundingterminal of your electrical service or supply panel witha continuous green insulated copper wire equivalent tothe circuit conductor supplying this equipment, but nosmaller than No. 12 AWG. In addition, a secondpressure wire connector is provided on the surface ofthe control box for bonding to local ground points. Toreduce the risk of electrical shock, this connectorshould be bonded with a No. 6 AWG copper wire toany metal ladders, water pipes, or any metal within 5feet of the spa.• Copper wire is recommended for all electricalconnections.•240 Volts, 60Hz, Single Phase, 50 or 60 amp. 4-wireservice (line 1, line 2, neutral, and ground),Note: The heater can be activated only withthe pump on low speed. Only the spa light can beoperating at the same time without disabling theheater. See your authorized dealer if select thisoption.Spas installed for 240 volt operation require a 4-wire, 50 or 60 amp. 240 volt sub-feed in non-metallicpipe to the spa equipment compartment (line 1, line 2,neutral, and ground).De plus, le raccord doit être effectué selon lesnormes CSA International (Canadian StandardAdministration).All connections must be done accordingly tothe CSA International regulation (Canadian StandardAdministration).A green colored terminal (or wire connectormarked “G”, or “GR”, “Grounding”) is provided in thecontrol box. To reduce the risk of electrical shock,connect this terminal or connector to the groundingterminal of your electrical service or supply panel witha continuous green insulated copper wire equivalent tothe circuit conductor supplying this equipment, but nosmaller than No. 12 AWG. In addition, a secondpressure wire connector is provided on the surface ofthe control box for bonding to local ground points. Toreduce the risk of electrical shock, this connectorshould be bonded with a No. 6 AWG copper wire toany metal ladders, water pipes, or any metal within 5feet of the spa.• Copper wire is recommended for all electricalconnections.Note: Units to be operated at 240 volts must have allelectrical connections made by a qualified licensedelectrician in accordance with the National ElectricCode and state/local codes in effect at the time ofinstallation.