2. Setup17 2. SetupFusion F1 Tablesaw © 2018 Laguna Tools 7/31/2018EN7. Plug in the tablesaw and SLOWLY rise the blade up and through the throat plateto the desired clearance.9. Re-adjust the throat plate back to operation height.LevelingTo level the machine, adjust the pads on the base of the saw.Dust CollectionUse the 4" port to install a dust collection line to the table saw.TROUBLE-SHOOTING: If you are experiencing dust collection issues, make sure to check these commonproblems:1. Remove motor cover and verify that the internal hose is fixed to the blade shroud port and the external 4"port.2. The optional zero clearance throat plate will supply better dust collection than the standard die cast throatplate.2.4 Functional SetupThe following setup sections explain how to change between different functionsthat the machine offers.Safety DevicesDANGER! Unplug tablesaw prior to changing safety devices or removing the throatplate.WARNING! No piece of safety equipment is enough to ensure safety by itself. 100% of your attention is requiredwhen operating this machine. Never lose focus on what you are doing and make sure you understand all warninglabels and safety precautions prior to operation.WARNING! Never operate with a broken or damaged spreader, riving knife, blade guard, or throat plate. Inspectcomponents regularly.WARNING! Only use a riving knife, spreader, or blade guard that is fit for the saw blade in use.WARNING! Only use a riving knife, spreader, or blade guard that is fit for the saw blade in use.Fig T008: Different Safety Devices. (1.1) locking handle. (1.2) adjustment screws. (2) Anti-kick pawls & Riving knife form blade guard (blade guard removed) (3) Blade Guard. (4)Riving Knife.There are three different safety devices included with the tablesaw. The completedblade guard assembly (3) offers the most protection and should be used wheneverpossible. Remove the blade guards and use the splitter/pawls (2) assembly only