10Fault Possible cause Correctiondrive doesn‘t function power supply interrupted plug in power supplyplug on switching panel disconnected connect plugdrive or control failure request after-sales serviceswitching panel doesn‘t function properly request after-sales servicemaximum load exceeded reduce / remove loadError messages on ‚Komfort‘ switching panel displayDisplay Possible cause CorrectionHOT drive control monitors duty cycle (time-dependent) and temperature. A valuehas been exceeded.wait until the ‚HOT‘ indica-tion has disappeared. Thetable will then continue tofunctionE00, E01, E02E81internal error disconnect power supplyand request after-salesserviceE12, E13, E14 malfunction disconnect power supply.Correct the external short-circuit and/or check thecable to the motors.Continue to use thecontrol as usualE24, E25, E26, E48, E49E62, E65current overload reduce / remove loadE55, E56(table rises / descendson one side only)control failure stop movement, requestafter-sales servciecable to motor disconnected connect plugE60 a collision has been registered remove causeE61 motor exchanged / connection broken reinstall table (see pg. 8)E63 external sensor / cable disconnected check plugsE64 authentication error reinstall table (see pg. 8)E70 alteration to motor drive configurationTroubleshooting