67 7Operating InstructionsMode Green Amber Red CommentStartup – Wait forLink status activeOff Off Blink twice persecondSystem will wait forlink status activebefore going intostandbyEnroll – Waitingfor setup buttonpressOff Off On for 1 second,off for 1 secondWait for monitor todirect user to pressbutton on monitorEnroll - Registrationwindow openOff Off Flashes rapidly(4 times a second)tap “enroll mymonitor” on appLink lost afterenrollmentOff Off Once per second Check status ofwireless routerSmoke Learning Off 1 sec on/1 sec offOff Test Smoke alarmCO Learning Off 100 ms on/1 sec offOff Test CO alarmStandby On Off Off Test monitor andalarms weeklyTest Mode – Step1: AcousticSelf-TestOn/Off On/Off On/Off Wait for Self-test tocomplete, app willshow status.Test Mode- Step2: Alarm TestOnce persecondOff Off Test alarm furthestfrom monitor, multiplealarms can be test.Test mode will exit2 minutes after lastalarm is detect.Alarm Detected Off Off Flashes rapidlywith a one secondpause.Follow instructionssupplied with youralarm.Snooze mode OnceeverytwosecondsOff Off Monitor detected pat-tern but notificationshave been disabledfor 10 minutes.Ignore Mode Onceevery 5secondsOff Off Monitor detectedpattern but owner hasdismissed alert. Monitorwill provide alert nexttime alarm is heard.Fault Notification Off On Once per second Unplug monitor andplug back in, run testto verify operation.RemoteLync LED Indicator Operation