GB - 30AnnexAnnex BB.1 CertificationB.1.1 CE MarkingCE marked frequency inverter and servo drives were developed and manufactured to comply with the regulationsof the Low-Voltage Directive 2006/95/EC.The inverter or servo drive must not be started until it is determined that the installation complies with the Machinedirective (2006/42/EG) as well as the EMC-directive (2004/108/EC)(note EN 60204).The frequency inverters and servo drives meet the requirements of the Low-Voltage Directive 2006/95/EC. Theharmonized standards of the series EN 61800-5-1 in connection with EN 60439-1 and EN 60146 were used.This is a product of limited availability in accordance with IEC 61800-3. This product may cause radio interferencein residential areas. In this case the operator may need to take corresponding measures.B.1.2 UL MarkingAcceptance according to UL is marked at KEB inverters with the adjacent logo on the typeplate.To be conform according to UL for the use on the North American and Canadian Market the following instructionsmust be observed (original text of the UL):• For control cabinet mounting as „Open Type“• Control Board Rating (max. 30Vdc, 1A)• Maximum Surrounding Air Temperature 45 °C (113 °F)• Overload protection at 130 % of inverter output rated current (see type plate)• Motor protection by adjustment of inverter parameters. For adjustement see application manual parametersPn.14 and Pn.15.• „Use 60/75°C copper conductors only“ for equipment rated 100 Amperes or less and “Use 75°C copper con-ductors only” for equipment rated grater than 100 Ampers.• Terminals - Torque Value for Field Wiring Terminals, the value to be according to the R/C Terminal Blockused.• Use in a pollution degree 2 environment• ”Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protectionmust be provided in accordance with the Manufacturer Instructions, National Electrical Code and any additi-onal local codes”, or the equivalent”.• For 240 V models:„Suitable for use on a circuit capable of delivering not more than x1) rms symmetrical amperes, 240 Voltsmaximum, when protected by fuses or see instruction manual for alternate BCP“For 480 V models:„Suitable for use on a circuit capable of delivering not more than x1) rms symmetrical amperes, 480 Voltsmaximum, when protected by fuses or see instruction manual for alternate BCP“For all models:For details of the branch circuits protection, which can be used, see technical data1) x depends on the housing size according to the following table:Housing size SC ratingB 5 kAA, D, E, G 10 kAH 18 kA