GB - 22Connection Terminals2.5 Terminal strips of the power circuitAttention! 230 V and 400 V-classes are possibleAll terminal strips meet the requirements on EN 60947-7-1 (IEC 60947-7-1)Housing size A Name Function Cable cross-section terminal no.Motor side Line side U, V, W Motor connection1PEUVWPAPB T1 T2– –+ +NL1PEPA, PB Connection for braking resistorT1, T2 Connection for temperature sensor++, – – Connection for braking module,Regenerative unit and supply unit or as DCvoltage input 250…370 VDC (230 V class)420…720 VDC (400 V class)L1, N 1-phase mains connectionL1, L2, L3 3-phase mains connectionPE Connection for shielding /earthingHousing size B, D, 12…14.E.400 V Name Function Cable cross-section terminal no.N/L2 L3PB U V WT1 T2--++L1L1, N 1-phase mains connection2L1, L2, L3 3-phase mains connectionU, V, W Motor connection++, PB Connection for braking resistor++, – – Connection for braking module,regenerating frontend and supply units or DCvoltage input250…370 VDC (230 V class)420…720 VDC (400 V class)T1, T2 Connection for temperature sensor 3PE, Connection for shielding /earthing 4Housing size E.200 V and ≥ 15.E.400 V Name Function Cable cross-section terminal no.L2 L3PB U V WT1 T2--++L1L1, L2, L3 3-phase mains connection5U, V, W Motor connection++, PB Connection for braking resistor++, – – Connection for braking module,regenerating frontend and supply units or DCvoltage input250…370 VDC (230 V class)420…720 VDC (400 V class)T1, T2 Connection for temperature sensor 3PE, Connection for shielding /earthing 4