#9.800-085.0 • Rev. 6/099PRESSURE WASHER OPERATOR’S MANUALSHUTTINg DOWN AND CLEAN-UPSTEP 1: Remove deter-gent suction tube fromcontainer and insert intoone gallon of fresh water.Slide nozzle forward forlow pressure or use blackdetergent nozzle. Pulltrigger on spray gun andsiphon fresh clean waterfor one minute.STEP 2: Turn off machineby turning switch to “OFF”switch.STEP 5: Disconnect thegarden hose from the wa-ter inlet on the machine.STEP 6: Disconnect thehigh pressure hose frompump discharge nipple.STEP 7: Engage thespray gun safety lock.STEP 4: Press trigger torelease water pressure.Pump WaterInlet Pump Discharge NippleSafetyLatchSTORAgECAUTIONPump StorageCAUTION: Always store your pres-sure washer in a location where thetemperature will not fall below 32°F(0°C). The pump in this machine issusceptible to permanent damage iffrozen.FREEzE DAMAGE IS NOT COvERED B Y WA R -RANTY.If you must store your pressure washer in a locationwhere the temperature is below 3°F, you can minimizethe chance of damage to your machine by draining yourmachine as follows:1. Stop the pressure washer and detach supply hoseand high pressure hose. Squeeze trigger of spraygun to drain all water from the wand and hose.. Restart pressure washer and let it run briefly (about5 seconds) until water no longer discharges fromthe high pressure outlet.STEP 3: Turn off watersupply.On/OffSwitch