MaintenanceEach use After thefirst 10h Each 25h Each 50h Yearly oreach 100hEach 2years oreach 300hMake sure that there are no fuel oroil leaks. *Make sure that nuts and screws aretightened. *Do a check of the fuel level and theengine oil level. ODo a check of the throttle controland the throttle wire. *Examine the air filter. Clean the airfilter if it is necessary. OClean the air filter. Replace the airfilter if it is necessary. O O O OReplace the engine oil. O O O OExamine and clean the spark plug.Replace the spark plug if it is neces-sary.O OReplace the spark plug. OExamine the vibration damping unitsfor damage. Refer toTo do a checkof the vibration damping system onpage 7.X XClean the spark arrester screen onthe muffler. O ODrain the fuel and clean the fueltank and the fuel filter. Replace thefuel filter if it is necessary.O O OTo clean the product• Remove concrete from the surfaces of the productafter each operation before the concrete becomeshard.• Use water and a brush to clean the product.CAUTION: Do not point the waterdirectly at electrical components or theengine.• Spray the beam with concrete form oil or concreterelease agent. This makes it easier to clean theproduct after the next operation.• Remove grease and oil from the handle.TroubleshootingProblem Cause SolutionThe product does not start. The fuel tank is empty. Fill fuel.The engine is cold. Close the choke.Engine failure. Refer to the engine manual.1294 - 004 - 01.12.2021 11 |